4.2 Func-CYCL": Automatic Datalogging with adjustable cycle-time

The Logger Cycle-Time is adjustable (see Configuration). For
example, setting "CYCL" = 60: A measurement is made every 60
seconds.
When the slow measurement "rAtE-Slo" is chosen, additionally a
low power function is available: "Lo.Po".
If "Lo.Po" is on, the device only will take a measurement at the
point of time of the recording. In between the recordings the mea-
suring shut's down. This decreases the power consumption enor-
mously and therefore is recommended e.g. for long time
recordings where no mains adapter is available.
Max. number of measurements:
Cycle time:
A measurement contains:
Slow measuring rate (rAtE SLo):
- Sensor 1 instantaneous value at that data point
- Sensor 1 Min-Peak, Max-Peak since last data point
- Sensor 2* instantaneous value at that data point
- Sensor 2* Min-Peak, Max-Peak since last data point
- Instantaneous difference (Sensor 1 - Sensor 2)* at that data point
- Min-Peak, Max-Peak of difference (Sensor 1 - Sensor 2)*, Min-
Fast measuring rate (rAtE FASt,P.dEt):
- Sensor 1 average since last data point
- Sensor 1 Min-Peak, Max-Peak since last data point
- Sensor 2* average since last data point
- Sensor 2* Min-Peak, Max-Peak since last data point
- Average difference (Sensor 1 - Sensor 2)* since last data point
- Min-Peak, Max-Peak of difference (Sensor 1 - Sensor 2)*, Min-
* Only for 2-channel version CPH 6200-D
Initiating Logging:
By pressing ´Store/Quit´ for 2 seconds recording will be initiated.
After that the display shows 'St.XXXX' for a short time whenever a
measurement is recorded. XXXX is the number of the data point
1... 9999.
WIKA Operating Instructions Hand-Held Pressure Indicator
Peak, Max-Peak since last data point
Peak, Max-Peak since last data point
9999