Action to be associated with "Trade" key: on specific days of the week and within specific time bands,
the programmed action can be triggered simply by pressing the button with the "Trade" symbol in the
Directory, and therefore not by entering any codes
Relay 1: the access code activates Relay 1 on the number keypad. This menu is only visible if the
Directory is paired with the Number keypad
Relay 2: the access code activates Relay 2 on the number keypad. This menu is only visible if the
Directory is paired with the Number keypad
Relay 1 and Relay 2: the access code activates Relay 1 and Relay 2 on the number keypad. This menu
is only visible if the Directory is paired with the Number keypad
Module SE output: the access code activates the SE output for the audio or audio/video module to
which the number keypad is connected (default)
Module relay output: the access code activates the relay output for the audio or audio/video module to
which the number keypad is connected
Actuator: the access code activates an actuator in the system
Actuator address: enter the address of the actuator art. 1256 (Simplebus) to be activated (this menu is
only visible if the "Actuator" option has been selected in the "Action to be associated with 'Trade' key"
menu)
Action to be associated with "Light" key: the programmed action can be triggered simply by pressing
the button with the
Relay 1: the access code activates Relay 1 on the number keypad. This menu is only visible if the
Directory is paired with the Number keypad
Relay 2: the access code activates Relay 2 on the number keypad. This menu is only visible if the
Directory is paired with the Number keypad
Relay 1 and Relay 2: the access code activates Relay 1 and Relay 2 on the number keypad. This menu
is only visible if the Directory is paired with the Number keypad
Module SE output: the access code activates the SE output for the audio or audio/video module to
which the number keypad is connected (default)
Module relay output: the access code activates the relay output for the audio or audio/video module to
which the number keypad is connected
Actuator: the access code activates an actuator in the system
Actuator address: enter the address of the actuator art. 1256 (Simplebus) to be activated (this menu is
only visible if the "Actuator" option has been selected in the "Action to be associated with 'Light' key"
menu)
Action to be associated with "Actuator" key: an actuator is triggered by pressing the key with the
symbol in the Directory
Actuator address: enter the address of actuator art. 1256 (Simplebus) you wish to trigger
Enable Bluetooth: enable operation of the Bluetooth module in the Directory
DATE/TIME
The Directory has an internal clock which maintains the date and time settings for 5 days even if the power
supply is cut off
Date: set the current date
Time: set the current time
Time difference: set the current time difference
Daylight Saving Time: enable Daylight Saving Time