4. Disinfectant settings

In the Disinfection menu item, you can change
all settings necessary for adding disinfectants.
Change from operating mode to set-up mode by
pressing the Mode key. Now press the „arrow
up" key and "channel 2" appears in the display.
Pressing the "OK" key takes you back to the
"Disinfection" sub-menu for adding disinfect-
ants.
Stop
controller
pH
controller
Disinfection
controller
max. Output (1)
Calibration
100%
Redox
min. Output (1)
max. Output (1)
10%
100%
min. Output (1)

D-action time (1)

10%
0 sec
D-action time (1)

I-reset time (1)

0 sec
0 sec
I-reset time (1)

P-band (1)

0 sec
100 mV
P-band (1)
100 mV

Max. Alarm (1)

Max. Alarm (1)
750 mV
750 mV

Min. Alarm (1)

Min. Alarm (1)
550 mV
550 mV
Setpoint (1)
Setpoint (1)
650 mV
650 mV
Mode
OK
Sub-menu
You can scroll through
the sub-menu by press-
ing the „arrow" keys.
When the option you want to change appears in
the display, press the "OK" key. A star appears in
the display. The value can now be changed using
the arrow keys. To save the changed value, press
„OK" again. Cancel by pressing the Mode key.
4.1
Setpoint Redox: [ 750 mV ]
The unit regulates and doses chlorine via redox
potential. First set the pH value in the pool water.
Then you have to add the desired amount of
chlorine to the pool water. We recommend 0.3-
0.6mg/litre using the DPD method. Now read
off the redox value on the control unit and set
the setpoint in accordance with the value you
have read off. As water differs in regard of its re-
dox values, even at identical chlorine concentra-
tions, we cannot provide any baseline setting. So
the redox value need not necessarily match the
default manufacturer' s reference setting. After 2-
3 weeks and at every pool refill, the setpoint must
be monitored, as the effective redox value levels
out only when the unit is operating. If the meas-
ured value undershoots the reference value, the
unit doses chlorine automatically until the set-
point is reached. At that point, the dosing pump
switches itself off.
Setpoint (2)
650 mV
Min. Alarm (↓) : [ 550 mV ]
4.2
Lower alarm value the undershooting of which
triggers an alarm. The alarm is shown in the dis-
play.
Max. Alarm (↑) : [ 750 mV ]
4.3
Upper alarm value, the exceeding of which trig-
gers an alarm. The alarm appears in the display.
Setpoint (2)
*
650 mV