For experts only
Test conditions:
Maximum test pressure 150 mbar
The high-pressure hose and gas cylinder must be connected�
Switch off all the gas appliances such as the heating, refrigerator
or gas hob in the recreational vehicle�
Open all quick-acting shut-off valves to the gas appliances and, if
necessary, the gas remote switch�
Disconnect the low-pressure section from the high-pressure sec-
tion� To do this, use the T20 Torx pin of the screw aid to turn the
black reset button in a clockwise direction until the reset button
jumps out�
Unscrew the screw cap of the test connection�
Connect the regulator test appliance with the test hose to the test
connection�
Check for leaks in accordance with the national regulations
(e�g� 607 in Germany)�
Unscrew the regulator test appliance from the test connection�
Screw the screw cap back onto the test connection�
Press the black reset button with the T20 Torx pin of the screw aid
in the housing and gently turn in an anti-clockwise direction�