EMC statement

• Upper Arm Blood Pressure Monitor meets the requirement of electromagnetics compatibility in
IEC60601-1-2.
• The user needs to install and use according to electromagnetism compatibility information which is
attached with it.
• Guidance and manufacture's declaration stated below.
Warning: : Don't near active HF surgical equipment and the RF shielded room of an ME system
for magnetic resonance imaging, where the intensity of EM disturbances is high.
Warning: Use of this equipment adjacent to or stacked with other equipment should be avoided
because it could result in improper operation. If such use is necessary, this equipment and the other
equipment should be observed to verify that they are operating normally.
Warning: Use of accessories and cables other than those specified or provided by the manufactur-
er of this equipment could result in increased electromagnetic emissions or decreased electromagnetic
immunity of this equipment and result in improper operation.
Warning: Portable RF communications equipment should be used no closer than 30 cm (12 inch-
es) to any part of the Upper Arm Blood Pressure Monitor, including cables specified by the manufacturer.
Otherwise, degradation of the performance of this equipment could result.

Manufacturer's EMC Statement

Guidance and Manufacturer's declaration – electromagnetic emissions
The Upper Ami Blood Pressure Monitors are intended for use in the electromagnetic environment
specified below. The customer or the user of the Upper Arm Blood Pressure Monitors should assure
that it is used in such an environment.
Emissions
RF emissions CISPR11
RF emissions CISPR11
Harmonic emissions
IEC 61000-3-2
Voltage fluctuations /
flicker emissions
IEC 61000-3-3
Compliance
Electromagnetic environment— guidance
The Upper Arm Blood Pressure Monitor including
AC-adapter uses RF energy only for its internal func-
Group 1
tion. Therefore, its RF emissions are very low and are
not Likely to cause any interference in nearby electronic
equipment.
Class B
The Upper Arm Blood Pressure Monitor including
Class A
AC-adapter is suitable for use in all establishments, in-
cluding domestic establishments and those directly con-
nected to the public low - voltage power supply network
Complies
that supplies buildings used for domestic purposes.