Herunterladen Inhalt Inhalt Diese Seite drucken

Bleeding; Maintenance - DeLonghi FRIO 12 Installationsanleitung

Klimaanlagen und wärmepumpen
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 57

BLEEDING

Humid air left inside the refrigerant circuit can cause com-
pressor malfunction. After having connected the indoor and
outdoor units, bleed the air and humidity from the refriger-
ant circuit using a vacuum pump.
(1) Unscrew and remove the caps from the 2-way and
3-way valves.
(2) Unscrew and remove the cap from the service valve.
(3) Connect the vacuum pump hose to the service valve.
(4) Operate the vacuum pump for 10-15 minutes until an
absolute vacuum of 10 mm Hg has been reached.
(5) With the vacuum pump still in operation, close the low-
pressure knob on the vacuum pump coupling. Stop the
vacuum pump.
(6) Open the 2-way valve by 1/4 turn and then close it after
10 seconds. Check all the joints for leaks using liquid
soap or an electronic leak device.
(7) Turn the body of the 2-way and 3-way valves. Discon-
nect the vacuum pump hose.
(8) Replace and tighten all the caps on the valves.

MAINTENANCE

Periodic maintenance is essential for keeping your air
conditioner efficient.
Before carrying out any maintenance, disconnect
from the power supply by putting the installation on/off
switch to "off".
INDOOR UNIT
Removing and cleaning the filter
air filter with the other hand
be washed with warm water (not exceeding 45°C). Leave
to dry in a cool and dry place.
INDOOR UNIT
UNITA' INTERNA
Refrigerant fluid direction of
Dir
efrigerante
flow
3-way valve
alvola a 3 vie
(7) Girare per
(7) Turn to open fully
Entrata
Service
aprire completamente
inlet
utile
(2) Turn
(1) Girare
(2) Turn
(2) Girare
(8) Fissare
Cappuccio
(8) Secure
della valvola
2
INSTALLER
2-way valve
alvola a 2 vie
(6) Aprire di 1/4 di giro
(6) Open by 1/4 turn
(7) Girare per aprire
(7) Turn to open fully
completamente
Cappuccio della valvola
(2) Turn
(1) Girare
(8) Secure
(8) Fissare
(8) Fissare
(8) Secure
Connect to the
Connettere all'
unità interna
indoor unit
INSTALLER
1
3
15

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Frio 9Frio 18

Inhaltsverzeichnis