HANDLING

Carefully remove the adhesive strips from the appli-
ance.
After having removed the packaging, check that the
contents are intact and complete.

INSTALLING THE INDOOR UNIT

Before starting installation, decide on the position of the
indoor and outdoor units, taking into account the minimum
clearance required around the units (see technical data
table).
Install the indoor unit in the room to be air conditioned,
avoiding installations in corridors or communal areas.
Install the indoor unit at a height of at least 2.5 m
from the ground.
To install, proceed as follows:
Installation of the mounting plate
-
Drill 32 mm deep holes in the wall for fixing the plate;
-
insert the plastic anchors into the hole;
-
fix the mounting plate using the self-tapping screws pro-
vided;
-
check that the mounting plate is correctly fixed;
-
using a spirit level, check that it is level.
Drilling a hole in the wall for the piping
-
Decide where to drill the hole in the wall for the piping
(if necessary) according to the position of the mounting
plate;
-
install a flexible flange through the hole in the wall to
keep the latter intact and clean.
The hole must slope downwards towards the exterior.
Installing the refrigerant, electrical and condensate
drainage pipes
-
Pass the pipe (for liquids and gas) through the hole in
the wall from the exterior or install it from the indoor side,
after having laid the pipes and connected the cables to
the indoor unit, ready for connection to the outdoor unit.
Decide whether or not to remove the knockout accord-
ing to the direction of the piping.
Water connections
Before installing the air conditioner, choose the direc-
tion for the pipes to exit; they may be arranged along
any one of the 4 directions shown in the figure:
The outdoor unit must always be kept upright.
Handling must be done by suitably equipped qualified
technical personnel using equipment that is suitable
for the weight of the appliance.
55 mm
Note: your mounting plate may be a different shape from
the one shown above, but the method of installation
is the same.
INDOORS
A
Ø 55 mm
Protective pipe
knockout
1
2

INSTALLER

INSTALLER
55 mm
OUTDOORS
2~5 cm
4
3
11