A 3-second long press of the Empty button enters or exits Wait Time Setting Mode. The Light
Bar will indicate the current Wait Time Setting. Subsequent short presses of the Empty button
will toggle through the settings shown below. After selecting the preferred setting,
a 3-second long press of the Empty button will save the setting.
3 minutes
1 Green Light displayed
7 minutes
2 Green Lights displayed
15 minutes
3 Green Lights displayed
25 minutes
4 Green Lights displayed
30 minutes
5 (All) Green Lights displayed

Control Panel Lockout

Control Panel Lockout disables button functions to prevent unwanted changes. The
Litter-Robot functions normally in Automatic Mode during Control Panel Lockout.
A 3-second long press of the Cycle + Reset buttons will enable or disable Control Panel
Lockout Mode. The Light Bar will momentarily flash red to confirm the status change.
While in Control Panel Lockout Mode, the Light Bar will flash white when any button is
pressed, indicating the Control Panel is locked.
While in Control Panel Lockout Mode, you can turn the unit OFF by pressing and holding the
Power button for 3 seconds.