English
Order code
Connection voltage
Power consumption
Protection class
Degree of protection
Nominal volume
Nominal pressure
Installation location
Design
Container
Mixed water quantity at 40 °C
Heat-up time from 10 °C to 65 °C (2 kW)
Connection thread inflow and outflow
Drain nozzle
Dimensions (width x height x depth)
Weight empty / weight filled
Thermal insulation
Temperature setting values
Colour
Load profile
1)
Energy efficiency class
1
Energy efficiency (ηwh
)
Annual energy consumption
Daily energy consumption
Set temperature
Weekly nominal power consumption
with intelligent regulation
Weekly nominal power consumption
without intelligent regulation
Overload protector
Protection against dry operation
1) Regulation of the commission EU 812/2013; EN 50440
2) EN 50440
Information on the energy-related efficiency and energy
consumption apply for smart operation.
EN-14
Unit
Litres
MPa (bar)
Litres
Minutes
Inch
Inch
mm
1)
kWh
2)
kWh
kWh
kWh
DHWE 50 S
W
50
Open or closed domestic hot water cylinder
Steel, enamelled, with magnesium protection anode
66
98
500 x 610 x 512
kg
28 / 78
°C
White (RAL 9010) with black operating panel
M
B
%
40
1241
6.42
°C
57
23.12
26.57
+
+
2204/C
DHWE 80 S
1/N/AC 230 V ~ 50/60 Hz
2000
I
IP24
80
0.6 (6)
Vertically on the wall
116
157
1/2"
3/8"
500 x 830 x 512
34 / 114
PU foam 40 mm (min.)
10 / 35 / 57 / 75
M
B
40
1226
6.47
57
24.18
28.41
+
+
www.dimplex.de
DHWE S
DHWE 100 S
100
137
196
500 x 975 x 512
39 / 139
L
C
40
2461
12.41
57
47.41
53.13
+
+