Herunterladen Inhalt Inhalt Diese Seite drucken

Technical Details - WANDERS Black Pearl Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Technical details

Door latch
Nominal capacity*
Flue collar
Maximum lumber supply
* the nominal heat is obtained with a chimney draft of 0.12 mBar
Fuel: wood logs (30 x 10 cm)
Maximum supply
Primary airvalve
Secundary air outlet
Fuel burning period
Flue gas values in accordance with DIN 4705, DIN 18895 part 2
When the door is closed and fueled with wood
Flue gas quantity
Flue gas temperature
Pre pressure
E ciency
CO at 13% O
2
Particulate matter
Certi cate institute
Test standard
Test report number
Target value for the volume of the space to be heated:
Not all spaces meet the present insulating values. According to DIN 18893, the following values can be taken
for the volume of the spaces to be heated:
If heating circumstances are favourable:
In less favourable circumstances:
In unfavourable circumstances:
For temporary heating you may assume a reduction of 25% for the volume to be heated if the interval is
more than 8 hours.
28
Black Pearl
I & II
Ba
8,0
kW
150
mm
3
kg
Black Pearl
8,2
g/s
345
C
0
0,12
mBar
77,7
%
0,09
%
27
mg/m
1625
EN13240
RRF - 4012 3076
calculate according to DIN 4701
135 m
3
95 m
3
3 pieces
maximum
maximum
about 1 hour