Warning: If you insist to charge the EP500 which has been connected into split
phase box already, please make sure the L1/L2/N wire is set at the right place or
the EP500 will be damaged.
L: Live wire N: Neutral wire
• The "Machine Type" setting on screen is used to enable or disable Split Phase
output.
Split-Phase output is achieved by bonding two EP500 into one power system to
double the available output power, voltage, and capacity.
• "Split Phase" is only used for connecting both *2 EP500 together (exclusive for
the 100-120V version of the EP500). A Fusion Box is required (sold separately).
• Launch Split Phase Function:
Note: Only one touchscreen will be active when two EP500 units are
connected.
If one of the EP500 is out of power, the Split Phase Bonding function will
deactivate automatically.
Step 1: Plug the output cables from each EP500 units to the Split Fusion box.
Step 2: Plug the communication cables from each of the two EP500 units to the
Split Fusion box.
Step 3: Set the Machine Type to "Split Phase" on either EP500 unit.
Step 4: Select "Master" or "Slave" on the operating EP500. Select "Master" will set
the operating EP500 as the one to control both two EP500. Select "Slave" will set
the operating EP500 as the other EP500 as the "Master" one.
EN-32