10.1.3. Turning ON the UPS Function
• Select "Setting" on the main touchscreen interface. Select "Next" and
select"Running Mode" to choose UPS Mode.
• The default working mode is "Standard UPS".
10.2. Enable UPS Running Mode
10.2.1 Standard UPS Mode
Offline UPS: Basic UPS Working Mode
EP500 will power your load directly from the grid and maintain a 100% charge.
When grid power fails, the EP500 switches to internal batteries to power the
circuit.
Online UPS: For Better-Than-Grid Power Quality
EP500 will power your load directly from the inverter/batteries and maintain a
100% charge. When grid power fails, batteries will continue to provide power.
10.2.2. PV Priority Mode
• PV Priority Mode: This mode is recommended for areas with stable grid power.
The battery will be recharged mainly by PV for power savings.
• Note: In PV Priority Mode, the EP500 can be only discharge to 20% of the
capacity, and will be charged via grid to 20%, the remaining 80% will be
charged by PV.
• User can change the setting to 100% to allow both solar (PV) & grid charging
manually on the touchscreen or in the App as the "Reserved Capacity" setting in
EN-29