Herunterladen Inhalt Inhalt Diese Seite drucken

General Safety Notes - Truma Trumatic C 6002 EH Gebrauchsanweisung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1

General safety notes

If the gas system is leaking or
if there is a smell of gas:
– extinguish all naked flames
– do not smoke
– switch off the appliances
– shut off the gas cylinder
– open windows and door
– do not actuate any
electrical switches
– have the entire system
checked by an expert!
Repairs may only
be carried out by an
expert!
A new O-ring must always be
installed after dismantling the
exhaust duct!
1. Any modifications to the
unit (including the exhaust
duct and the cowl) or the use
of spare parts and accesso-
ries that are important to the
operation of the system
(e.g. the time switch) that are
not original Truma parts and
failure to follow the installa-
tion and operating instruc-
tions will cancel the warranty
and indemnify Truma from
any liability claims. It also be-
comes illegal to use the appli-
ance, and in some countries
this even makes it illegal to
use the vehicle.
2. The operating pressure
of the gas supply must cor-
respond with the operat-
ing pressure of the device
(30 mbar).
3. Liquid gas systems must
comply with the technical
and administrative regula-
tions of the respective coun-
try of use (e.g. EN 1949 for
vehicles or EN ISO 10239 for
boats in Europe). National di-
rectives and regulations (e.g.
DVGW worksheet G 607 for
vehicles and G 608 for boats
in Germany) must be com-
plied with.
The testing of the gas sys-
tem must be repeated every
two years by a qualified
specialist and, if appropriate,
confirmed on the inspection
certificate (in Germany, for
example, DVGW Worksheet
G 607 for motor vehicles or
G 608 for boats).
The vehicle owner is
always responsible for
arranging the inspection.
4. Liquid gas equipment must
not be used when refuelling,
in multi-storey car parks, in
garages or on ferries.
5. During the initial operation
of a brand new appliance (or
after it has not been used for
some time), a slight amount
of fumes and smell may be
noticed for a short while. It
is a good idea to heat the
device up several times in
mixed/summer operation
(60°C) and to make sure that
the area is well ventilated.
6. If the burner makes an
unusual noise or if the flame
lifts off, it is likely that the
regulator is faulty and it is
essential to have it checked.
7. Items sensitive to heat
(e.g. spray cans) must not be
stored in the installation area,
since excess temperatures
may under certain circum-
stances be incurred there.
8. Only pressure regulators
that comply with EN 12864
(in vehicles) and EN ISO
10239 (for boats) with a fixed
delivery pressure of 30 mbar
must be used for the gas
system. The flow rate of the
pressure regulator must cor-
respond to at least the maxi-
mum consumption of all de-
vices installed by the system
manufacturer.
For vehicles we recommend
the Truma SecuMotion gas
pressure regulator and the
Truma DuoComfort automatic
changeover valve for the
two-cylinder system.
At temperatures of around
0°C or less the gas pressure
regulator and the changeover
valve must be operated using
the EisEx de-icing system.
Controller connecting hoses
that meet national regula-
tions must always be used
in the respective country
for which the equipment is
destined. These hoses must
be checked regularly for brit-
tleness. Winter-proof special
hoses must always be used
if the equipment is operated
during the winter.
Pressure regulating equip-
ment and hoses must be
replaced with new ones no
more than 10 years after the
date of manufacture (every
8 years if used commercially).
This is the responsibility of
the operator.
Accessories
1
2
3
MODIMIDOFRSASO
Truma Timer ZUC 2 complete
with 3 m connecting cable
(part no. 34042-01).
Remote control for electrical
safety/drain valve, complete
with 3 m connecting cable
(part no. 34170-01).
The electrical accessories are
fitted with a plug and can be
connected individually.
Extension cables for the con-
trol panel, the ZUC 2 timer
and remote control panel for
the drain valve are available if
required.
Cowl extension KVC for
winter camping
(part no. 34070-01).
The cowl extension must be
removed whilst driving.
Double-skin leadthrough for
caravan-double-skin roofs
(part no. 34080-01).
As standard, Truma supplies
a suitable cover frame, in ag-
ate grey colour, for every con-
trol panel/every time switch.
Shrouding frames are avail-
able in different colours as a
special accessory, and side
sections for finishing off the
shrouding frames are also
available in 8 different
colours.
Please contact your dealer.
Clip rows
(part no. 34000-65900).
For installing several Truma
control panels next to one
another.
Surface-mounting frame for
Truma control panel
(part no. 40000-52600).
Combination with the side
pieces is not possible.
13