Herunterladen Inhalt Inhalt Diese Seite drucken

Electrical Connection - Fagor M-G910 Installations-, Gebrauchs- Und Wartungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 48
Replace the control holder panels and the controls.

4.4 Electrical connection

An AUTHORISED TECHNICIAN should always carry out the appliance's electrical connection.
The legal standards in force in each country regarding connection to the mains should be taken into
account.
• Check that the mains voltage corresponds to that indicated on the nameplate.
• The electric cable should be flexible, with an oil-proof covering, and it should not
• The cross-section of the power cable must be suitable for the rated current of the
• The appliance must be connected to earth using the connection on the appliance
• When several appliances are installed in series, they should be earthed to each
• An easily accessible omnipolar magneto-thermal circuit breaker of suitable
• An easily accessible differential protection device of suitable capacity should be
• If any faults are observed during the installation, the supplier should be notified
• Before replacing the switchboard cover, fasten the electric supply cable
The manufacturer will not be held liable for any personal or material damage to the
machine resulting from incorrect installation or failure to comply with the
manufacturer's specifications.
weigh less than the cable in an ordinary sleeve made of standard polychloroprene
or an equivalent synthetic elastomer (H05RN-F).
machine. (Table 2)
connection terminal board. The earth cable should be longer than the other wires.
The manufacturer will not be held liable for damage originated by failure to observe
this requirement.
other using the point assigned for this purpose, located at the rear of the appliance.
capacity should be installed next to the appliance, with a minimum gap of 3 mm
between contacts. This switch should be used to disconnect the appliance during
installation, repair, cleaning and maintenance work. It should have locking/labelling
capacities. The manufacturer will not be held liable for damage originated by failure
to observe this requirement.
installed next to the appliance. The manufacturer will not be held liable for damage
originated by failure to observe this requirement.
immediately.
tightly to the stuffing box.
30

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis