Herunterladen Inhalt Inhalt Diese Seite drucken

Dimplex LA 1118BW Montage- Und Gebrauchsanweisungen Seite 34

Luft-wasser-wärmepumpe für außenaufstellung
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

English
11 Cooling capacity / COP
11.1 Cooling capacity / COP
1. For air temperatures between -22°C and -5°C, flow temperature increasing from 45? to 60?.
2. Operation with 2 compressors
3. Operation with 1 compressor
4. These data indicate the size and capacity of the system according to EN 14511. For an analysis of the economic and energy efficiency of the system, other parameters, in
particular the defrosting capacity and regulation, should also be taken into consideration. These figures are only achieved with clean heat exchangers. Instructions for care,
commissioning and operation can be found in the relevant sections of the installation and operation instructions. The specified values have the following meaning, e.g. A7/
W35: outside air temperature 7 °C and heating water flow temperature 35 °C.
5. The heat output and COP is reduced by approx. 5 % in lower operation
6. When using the optional weather protection hood (accessory), the sound level is reduced to the specified values.
7. The specified sound pressure level represents the free sound area level. The measured value can deviate by up to 16 dB(A), depending on the installation location.
8. Condition as delivered 6 kW
9. Note that additional space is required for pipe connections, operation and maintenance.
10.See CE declaration of conformity
11.The heat circulating pump and the heat pump manager must always be ready for operation.
12.The coefficient of performance (COP) in partial load operation can be increased by selecting "energy-optimised heating operation" (natural defrosting)
13.The maximum sound power level under full load can increase by up to 5 dB(A).
EN-14
4 13
Performance level
at A27 / W18
at A27 / W9
at A27 / W7
at A35 / W18
at A35 / W9
at A35 / W7
452168.66.24 · FD 0206
1
kW / ---
8.2 / 4.5
kW / ---
kW / ---
6.0 / 3.4
kW / ---
6.7 / 3.2
kW / ---
kW / ---
5.2 / 2.6
LA 1118BW(C)
EN 14511
2
15.4 / 3.7
12.7 / 3.2
---
14.0 / 3.1
12.2 / 2.7
---
www.glendimplex.de

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

La 1118bwc

Inhaltsverzeichnis