Dimplex LA 1118BW Montage- Und Gebrauchsanweisungen Seite 31

Luft-wasser-wärmepumpe für außenaufstellung
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

LA 1118BW(C)
for expansion vessel
6.12 Anode diameter
6.13 Anode length
6.14 Anode connection thread
6.15 Weight of the transport unit(s) incl. packaging
7
Electrical connection
7.1
Supply voltage / fusing / RCD type
7.2
Control voltage / fusing by WPM
7.3
Degree of protection according to EN 60529
7.4
Starting current limiter
7.5
Rotary field monitoring
7.6
Starting current with soft starter
7.7
Nominal power consumption A2/W35/ max. power consumption
Nominal current A2 /W35 / cos 
7.8
7.9
Power consumption of compressor protection (per compressor)
7.10 Power consumption of fan
7.11 Control voltage, fusing
7.12 Supply voltage / fusing (∑ P = 3.5 kW)
Supply voltage / fusing (∑ P = 3.5 kW) HWK
8
Complies with the European safety regulations
9
Additional model features
9.1
Type of defrosting
9.2
Frost protection, condensate tray /
Water in device protected against freezing
9.3
Maximum operating pressure (heat sink)
9.4
Energy efficiency class / energy efficiency (low temperature)
9.5
Energy efficiency class / energy efficiency (mean temperature)
4
10 Heat output COP
10.1 Heat output / COP
1. For air temperatures between -22°C and -5°C, flow temperature increasing from 45? t
2. Operation with 2 compressors
3. Operation with 1 comressor
4. These data indicate the size and capacity of the system according to EN 14511. For an analysis of the economic and energy efficiency of the system, other parameters, in
particular the defrosting capacity and regulation, should also be taken into consideration. These figures are only achieved with clean heat exchangers. Instructions for care,
commissioning and operation can be found in the relevant sections of the installation and operation instructions. The specified values have the following meaning, e.g. A7/
W35: outside air temperature 7 °C and heating water flow temperature 35 °C.
5. The heat output and COP is reduced by approx. 5 % in lower operation
6. When using the optional weather protection hood (accessory), the sound level is reduced to the specified values.
7. The specified sound pressure level represents the free sound area level. The measured value can deviate by up to 16 dB(A), depending on the installation location.
8. condition as delivered 6 kW
9. Note that additional space is required for pipe connections, operation and maintenance.
10.See CE declaration of conformity
11.The heat circulating pump and the heat pump manager must always be ready for operation.
12.The coefficient of performance (COP) in partial load operation can be increased by selecting "energy-optimised heating operation" (natural defrosting)
www.glendimplex.de
HWK
HWK
HWK
HWK
4
HWK
HWK
HWK
11
Performance level
at A-7 / W35
at A2 / W35
at A7 / W35
at A7 / W45
at A7 / W55
at A10 / W35
452168.66.24 · FD 0206
inches
mm
mm
inches
kg
3~/N/PE 400 V (50 Hz) / C13 A / B
1~/N/PE 230 V (50 Hz) / 4 AT
A
kW
A / ---
W / ---
70 / thermostatically controlled
W
1~ / N / PE 230V (50Hz) / B63A
3~ / N / PE 400V (50Hz) / B25A
1~ / N / PE 230V (50Hz) / B16A
3~ / N / PE 400V (50Hz) / B10A
Reverse circulation
bar
1
kW / ---
5.6 / 3.3
kW / ---
7.3 / 4.3
kW / ---
8.4 / 5.0
kW / ---
8.1 / 3.9
kW / ---
7.7 / 3.2
kW / ---
8.8 / 5.4
English
1" AG/FL
33
690
1 1/4" IG
210
IP 24
Soft starter
Yes
21
3.24 / 6.8
5.9 / 0.8
up to 200
10
Yes
3.0
A++ / 168 %
A++ / 133 %
EN 14511
2
10.5 / 3.2
12
12.3 / 3.9 (4.0)
EN-11

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

La 1118bwc

Inhaltsverzeichnis