Before Startup

Illustrations on Page 2
Illustration
Mount loose parts delivered with appliance
prior to start-up.
Illustration
Push the high pressure hose into the
trigger gun until it locks audibly.
Note: Make sure the connection nipple
is aligned correctly.
Check the secure connection by pulling
on the high-pressure hose.

Water supply

According to the applicable regula-
tions, the appliance must never be
used on the drinking water supply
without a system separator. Use a
suitable system separator manufactured by
KÄRCHER; or, as an alternative, a system
separator as per EN 12729 Type BA. Water
flowing through a system separator is con-
sidered non-drinkable.
Note: Impurities in the water can damage
the high-pressure pump and accessories.
For protection, the use of the KÄRCHER
water filter (optional accessory, order no.
4.730-059) is recommended.
Water supply from mains
Observe regulations of water supplier.
For connection values, see type plate/tech-
nical data.
Use a fibre-reinforced water hose (not
included) with a standard coupling.
(Minimum diameter 1/2 inch (13 mm),
minimum length 7.5 m).
Illustration
Screw the coupling element (supplied)
to the water connection on the appli-
ance.
Push the water supply hose onto the
coupling unit, then connect it to the wa-
ter supply.
Drawing in water from open reservoirs
This high-pressure cleaner is suited to work
with the KÄRCHER suction hose with back-
flow valve (Optional accessory, order no.
6
Deutsch
4.440-238) to draw in surface water, e.g.
from water butts or ponds (see specifica-
tions for max. suction height).
Fill the KÄRCHER suction hose with
backflow valve with water, screw to wa-
ter supply and hang into the water butt.
Separate the high pressure hose from
the high pressure connection of the ap-
pliance.
Switch the appliance on (I/ON) for a
max. of 2 minutes and wait until the wa-
ter exits the high-pressure connection
without bubbles.
Turn off the appliance "0/OFF".
Start up
Caution
Dry runs lasting longer than two minutes
lead to damages to the high pressure
pump. If the appliance does not build up
pressure within two minutes, switch it off
and proceed as instructed in the Chapter
"Troubleshooting".
Illustration
Connect the high pressure hose to the
high pressure connection of the appli-
ance.
Illustration
Push the spray lance into the trigger
gun and fasten it by turning it through
90°.
Illustration
Completely open the water tap.
Insert the mains plug into the socket.
Illustration
Turn on the appliance "I/ON".
Operation
Danger
The trigger gun is subjected to a recoil force
when the water jet is discharged. Make
sure that you have a firm footing and are
also holding the trigger gun and spray lance
firmly.
Illustration
Unlock the lever on the trigger gun.