1.0 MULTIFUOCO VENTILATION KIT WITH REMOTE CONTROL
DT2011488-00
The fi replaces Piazzetta are predisposed for the
installation of the "Multifuoco Ventilation kit with remote
control". This system, patented by Gruppo Piazzetta
S.p.A., makes it possible to heat one or more rooms
uniformly thus preventing layering of hot air near the
ceiling.
Installation of the fan kit does not entail an
increase in the heat output of the appliance, but
rather the heating of the room (or rooms) uniformly in so
far that this system (that allows aspiration from above
and exhaust from below) creates a recycling of hot air
which impedes ceiling stratifi cation.
The Fan kit is provided of: a ventilation fan (which has
3
an airfl ow of approximately 220 m
/ h, power capacity
of 47 Watts) wired withy cable and remote control box,
PT probe, portable remote control with 4 buttons (fed by
low-voltage batteries), spacers, fi xation elements.
The remote control is equipped with an (ON/OFF) button
which has two functions, i.e. "turning on / turning off", a
DT2032143-00
button for switching to automatic operation (AUTO) and
two buttons (+/-) governing the fan operating speed
(minimum speed V1, average speed V2, maximum
average speed V3, maximum speed, V4).
To identify the operating speed setting of the fan, simply
listen to the number of beeps emitted when the + and
- buttons of the remote control are pressed (1 beep for
each increase in speed), when manually shutting off
the fan, a long beep is heard which signifi es that the
system has been turned off.
The probe allows the fan to automatically start and stop
when the temperature reaches the turn-on and turn-off
thresholds.