Problem
The glass window is sooty
The chimney is too small
The stove emits a strong odor and
smokes externally
Flue gas escapes when stoking up
and during the heating phase
The fire is too weak and/or goes out Air control closed (-)
The room is not warm enough
The fire burns down too quickly and
uncontrollably
Ceramic windows become sooty
very quickly
98
EN
Cause
Insufficient draft
incorrect operation of the air control It is imperative that the air controller
excessively large pieces of firewood
firewood too damp
Operating temperature has not been
reached
The chimney draft is insufficient
Exhaust ducts and combustion
chamber sooted up
Stove-enameling phase of the var-
nish
The stove surface is dusty/soiled
Chimney draft too low, flue pipe con-
nection leaky
Door opened before combusted
down to embers
Wood too damp
External temperature too high
(>15 °C)
Convection air grille closed
Chimney draft too high
Air control open (+)
Seals worn
Firebox door not closed properly
Chimney draft too high
Unsuitable wood used
Operating manual Clou Compact 2.0
Solution
from time to time (depending on
use) the window must be cleaned
with glass cleaner
Clarification with chimney sweeper
(poss extend chimney/measure
draft)
is operated in accordance with the
instructions (if secondary air is closed
too far, the glass pane will become
sooty very quickly)
Comply with quantity and size ac-
cording to the instructions
Use more fuel, dry wood (< 15 % re-
sidual moisture), pay attention to air
regulation
Ask your chimney sweep to carry out
a draft measurement
Use more fuel, dry wood (< 15 % re-
sidual moisture), pay attention to air
regulation
During the first heating cycles, the
varnish hardens and smells in the
process
Keep the surfaces of the stove clean
Keep the floor area clean around the
stove
Check connection points and if ne-
cessary reseal
Check chimney draft
Only stoke up when only embers are
present (no more visible flames)
Air control open (+)
Are you using dry wood (< 15 % re-
sidual moisture)?
Open convection air grille
Clarification with chimney sweeper
(poss shorten chimney/measure
draft)
Throttle combustion air supply after
the operating temperature has been
reached in the firebox (+ / -)
Check whether the seals on the in-
side of the door are continuous and
in working order, if necessary re-
place
Close firebox door
Clarification with chimney sweeper
(poss shorten chimney/measure
draft)
Use dry unrefined wood. See inform-
ation about this in the Fuel section