32/48
Bosch Rexroth AG
Product description
CAUTION
Risk of damage to persons and property!
The voltage circuits on terminal XDN2 are
safely isolated from the mains circuit (safe
isolation in accordance with EN50178, PELV).
The requirements for safe isolation of
electric circuits must be observed if using
the connection options on this terminal.
Tab.5: XDN2
Pin Signal
Description/
function
24 V supply
1
VEE
voltage
24 V supply
2
VEE
voltage
3
VEE_NH
24 V supply
voltage for emer-
gency OFF circuit
ES
emergency OFF
4
joint feed for mo-
tor contactors
Reference poten-
5
GND
tial for all voltages
Reference poten-
6
GND
tial for all voltages
7
GND
Reference poten-
tial for all voltages
The total current that can be drawn at pin 1 and 2
a)
is max. 1 A (current limiting).
Current limited to 1 A.
b)
NOTE
The maximum torque at the bolted
connections of the terminals at XDN2 must
not exceed 0.3 Nm.
The motor contactors integrated in the servo
amplifiers are operated centrally by switching the
emergency OFF.
Voltage/cur-
Insufficient emergency OFF equipment!
rent
Danger to life through electrical or mechanical
forces
24 V= / 1 A
a)
24 V= / 1 A
a)
24 V= / 0,3 A
b)
24 V / 30 mA
PE potential
PE potential
PE potential
Risk of damage to persons and property!
VM350 | 3609929B32/2021-09
DANGER
The user is responsible for determining the
necessity of an emergency OFF, its imple-
mentation, and the risk analysis! Make
sure the emergency OFF equipment is
accessible and effective. Release of the
emergency OFF equipment may not result
in an uncontrolled system restart!
Check the function of the emergency OFF
equipment before switching the system
on. If using the voltage circuits at the
emergency OFF terminal, observe the
requirements for the safe isolation of
electric circuits.
CAUTION
The user is obliged to maintain the
system-specific requirements for an
emergency OFF system.
When using external mains contactors in
superior emergency OFF circuits, observe
the restarting time of 10 seconds for
single switching and 30 seconds for
repeated switching.