SYSTEM SET UP

EN
When you start a charge process, the integral
safety time automatically starts running at the same
time. This is programmed to prevent overcharge the
battery if it proves to be faulty, or if the termination
circuit cannot fully detect the battery. The value for the
safety time should be generous enough to allow a full
charge of the battery.
Safe time Calculation
When charging NiMH or NiCd batteries, divide the
capacity by current, then divide the result by 11.9,
set this number as the value for safety time setting.
If the charger stopped at this threshold, about 140%
of the capacity will have been fed into the battery.
For example:
Capacity
Current
2000mAh
2.0A
3300mAh
3.0A
1000mAh
1.2A
This program sets the maximum charge capacity
that will be supplied to the battery during charge. If
the deltapack voltage is not detected nor the safety
time expired by any reason, this feature will auto-
matically stop the process at the selected capacity
value.
The battery's internal chemical reaction will cause
the temperature of the battery to rise. If the tempera-
ture limit is reached, the process will be terminated.
You can choose the temperature displayed by
Celsius or Fahrenheit as you like.
50
Safety Time
(2000/2.0=1000)/11.9=84 minutes
(3300/3.0=1100)/11.9=92 minutes
(1000/1.2=833)/11.9=70 minutes