SYSTEM SETTINGS MENU

Long press the CH1 roller wheel to activate the system default menu.
Language
MAX Input Power
MIN Input Voltage
Power Distribution
Capacity Cut
Time Cut
Temperature Cut
Backlight
Volume
Servo Pulse Period
Servo Pulse Step
About
Factory Reset
Back
Max Input Power: When the input power can not reach the charger's maximum
working power requirement (700W), to ensure stable and safe operation of the
HERAKLES NEO, this value should be adjusted according to the input power
source used for the charger. For example, when using a 20V/20A DC power
supply, this value should be set to 400W (P=U X I).
Min Input Power: When the user takes a battery as the input power source, this
setting can protect the battery from being over-discharged. When the charger de-
tects an input voltage lower than the setting value, then the charger will stop the
current task and remind the user with showing" DC IN TOO LOW". For example,
when using a 6S LiPo as a power source, we can set this value at 21.0V to protect
the battery from being overdischarged.
English, German, French, Simplified Chinese, Trad. Chinese
Adjustable from 100W-700W (if use DC input source)
Adjustable from 9V-24V (if use DC input source)
Support power distribution
Terminates charge process when reach this value
Maximum capacity can be adjusted by user
Terminates charge process when exceeding time set by user
Battery temperature protection
(external temperature cable is required)
Three options-High, Medium, Low
Four options- High, Medium, Low and Off
Servo PWM signal period
Servo PWM signal pulse width increment
Software version and information
Returns all settings to factory default values
Return to last program or menu