LITHIUM BATTERY (LiPo/LiFe/LiIon/LiHV) PROGRAM
Elapsed
Number
time
of cells
Charging
current

'STORAGE' CONTROL OF LITHIUM BATTERY

This function is for charging/discharging batteries which are not used at once. This
program is designed for charging or discharging of batteries of specific original
state. They are classified by types: 3.80V LiPo, 3.30V LiFe, 3.70V LiIon, and 3. 90V
LiHV. The program will begin to discharge if the original state of battery exceeds
the voltage level of storage.
Batt type
Stop
EN
Current
Supplied
voltage
capacity
battery
> 3 seconds
If both numbers are identical you can start char-
ging process. If not, press BATT TYPE/STOP
button to go back to previous screen to recheck
the number of cells of the battery pack before
going ahead.
This screen shows the real-time status during
charge process. Press BATT TYPE/ STOP button
once to stop the charge process.
At this screen, you can set up the current
and voltage of the battery pack. Charging and
discharging will make the batteries come to the
voltage level of storage state.
This screen displays the number of cells you set
up and the processor detects.
R=Number of cells detected by charger.
S=Number of cells set by you at the previous
screen.
If both numbers are identical you can start
charging process by press START/ENTER
button. If not, press BATT TYPE/STOP button
to go back to previous screen to recheck the
number of cells of the battery pack before going
ahead.