2.6

Residual risks and protective measures

Original operating manual for oil-fired pasteurizers EHA40, EHA66, EHA90
16.02.2021
CAUTION
Risk of electric shock!
CAUTION
Hot surface!
CAUTION
Risk of slipping!
CAUTION
Scalding by skin contact with hot liquids.
Protective measure: Demonstrate danger with a warning sign.
CAUTION
The juice outlet becomes very hot, this can lead to burns on skin contact!
Protective measure: Demonstrate danger with a warning sign.
CAUTION
Risk of slipping or falling due to nearby wet floor!
Protective measure: Demonstrate danger with a warning sign.
Wear protective gloves
When working on the machine, wear suitable protective gloves (e.g. cut and / or
heatproof protection).
Wear eye protection
When working on the machine, wear suitable eye protection.