2.2 Warranty

For the general conditions of the warranty, please con-
tact your local official distributor. In case of replace-
ment of components, always ask for original spare
parts.

3 INSTALLATION

3.1 Transportation

The net weight and the gross weight of this equipment
are shown in the external packaging.
The appliance can be loaded and unloaded from the
means of transport using a forklift truck or a pallet truck
with forks longer than half of the unit. The lifting vehi-
cle must be selected based on the dimensions of the
packed machine/components and with proper capac-
ity.
When handling the appliance, all necessary precau-
tions must be taken to avoid damaging it.

3.2 Unpacking and disposal

Remove the cardboard packaging from the base
on which it rests. Then lift the machine with suitable
means (forklift truck or similar), remove the wooden
base and position the machine in the intended place.
After removing the packaging, make sure that the ma-
chine/sub-assemblies are intact. If in doubt, do not use
it and contact the reseller.
Remove the protective PVC film on the stainless steel
panels on all sides.
NOTE: all the components of the packaging must be
disposed of according to the regulations in force in the
country in which the device is used. In any case, noth-
ing must be dispersed in the environment.

3.3 Positioning

The appliance:
- must be installed in places where it can be
checked by qualified personnel.
- must not be installed outdoors.
- must not be installed in dusty environments (Fig.
8).
- must not be put in places with the presence of
water jets.
- must not be washed with water jets.
- must be installed and tested in full compliance
with accident prevention regulations, traditional
regulations and current regulations.
- must be positioned at a minimum distance of 200
mm from the rear wall(fig. 3)
- Avoid places exposed to direct sun rays, closed
spaces with high temperatures and poor ventila-
tion and avoid installing the machine close to any
source of heat (Fig. 6)
• Match the ice maker to your storage bin, securing
the connection with the two screws supplied with the
machine (Fig.10)
8
• Place the ice maker/storage bin in the designated
place, making sure that it is on the level. This is nec-
essary to ensure that an even distribution of water on
the evaporator and a regular emptying of the ice cube
plate. The feet of the storage bin can be adjusted to
achieve this.
• Release the deflector and remove the stops applied
to prevent damage during transport (Fig.14)
• Install the metal deflector in the rear part of the appli-
ance with the screws supplied (Fig.16).
The installer should check any fire prevention require-
ments (contact the local fire brigades for proper indi-
cations).
If the appliances are not levelled, their operation and
condensation discharge might be compromised.
1
Before commissioning the ice maker, perform
the following operations:
1. Check that the device has not suffered any damage
due to transportation (fig.2)
2. Extract from the bin, all supplied materials: feeding
tube, exhaust pipe, documentation and any accesso-
ries.
3. Clean the inside of the bin with a sponge soaked
in warm water mixed with a little bicarbonate of soda;
rinse with clean water and properly dry.
4. Place the ice maker in a definitive place making
sure that it is perfectly flat (fig.3)
i
Note: when choosing the environment where to
install the machine, make sure that:
- the ambient temperature does not drop under
10°C (50°F) and does not exceed 43°C (110° F).
- the water temperature should not be under 10°C
(50°F) and should not exceed 32°C (90°F) (fig.4).
- the feed water pressure should not be under 0.1 MPa
(1 bar) and it should not exceed 0.5 MPa (5 bar). If the
pressure exceeds 0.5 MPa, install a pressure reducer
on the water supply to the machine (fig.7).
• the water conductivity must not be less than 10 μs /
cm at 25° C ambient temperature.
- the machine should be kept away from sources of
heat and in a well-ventilated place (fig.6).
I
Connect only to the drinking water network
(Fig. 5)
5. Before performing the electrical connections, per-
form the hydraulic al ones.
6. Connect the 3/4" supply pipe (supplied) from the
machine to the water supply line (Fig.7-6).
• Attach the flexible hose to the machine's discharge
fitting (Fig.7-8). For a perfect water intake from the de-
vice, provide a minimum 3% incline of the pipe check-
ing that it is not subject to bottlenecks or siphoning. The
pipes should discharge into an open siphon (Fig.7-10).
For appliances with water condensation systems, at-
tach:
• a 3/4" pipe from the condensation water supply to
connection 9 of
Fig.7
of the machine