Herunterladen Inhalt Inhalt Diese Seite drucken

Anhang 2 Parametertabelle - Kobold NGR-Serie Bedienungsanleitung

Fuellstandssensor
Inhaltsverzeichnis

Werbung

NGR
IO-Link Operating Instructions for NGR-XXXXXX
Physical Layer
1. .
SIO Modus
Min Cycle Time
Baudrate
Process Data Length
2. . Process Data
3. . Service Data
IO-Link specific
Index
Name
dec (hex)
16 (0x10)
Vendor Name
18 (0x12)
Product Name
19 (0x13)
Product ID
21 (0x15)
Serial Number
22 (0x16)
Hardware Version
23 (0x17)
Firmware Version
24 (0x18)
Application Specific Tag
Kobold device specific
Index
Name
dec (hex)
64 (0x40)
Device Specific Tag
90 (0x5A)
Part Number
100 (0x64)
SP1/FH1
101 (0x65)
RP1/FL1
102 (0x66)
OU1
103 (0x67)
SimQ1
104 (0x68)
SP2/FH2
105 (0x69)
RP2/FL2
106 (0x6A)
OU2
ro = read only, wo = write only, rw = read/write
61

Anhang 2 Parametertabelle

yes
16000 µs
COM2
32 Bit
Format
Length
(Offset)
String
64 Byte
String
64 Byte
String
64 Byte
String
16 Byte
String
64 Byte
String
64 Byte
S
String
tri
Byte
Format
Length
(Offset)
String
16 Byte
String
8 Byte
UInt
16 Bit
UInt
16 Bit
UInt
8 Bit
UInt
8 Bit
UInt
16 Bit
UInt
16 Bit
UInt
8 Bit
1
Access
Default
Value
ro
Kobold Messring
ro
NGR-
ro
NGR-XXXXXX
ro
ro
ro
rw
***
1
Access
Default
Value / Range
Value
rw
***
ro
Part Number
rw
0...6005
Q1 SP1: Setpoint / FH1: High Limit Point
rw
0...6005
Q1 RP1: Resetpoint / FL1: Low Limit Point
rw
0 = Q1_Hno
Q1 Function
1 = Q1_Hnc
2 = Q1_Fno
3 = Q1_Fnc
4 = Q1_Eno
5 = Q1_Enc
rw
0 = Q1Norm
Simulate Q1
1 = Q1On
2 = Q1Off
rw
0...6005
Q2 SP2: Setpoint / FH2: High Limit Point
rw
0...6005
Q2 RP2: Resetpoint / FL2: Low Limit Point
rw
0 = Q2_Hno
Q2 Function
1 = Q2_Hnc
2 = Q2_Fno
3 = Q2_Fnc
4 = Q2_Eno
5 = Q2_Enc
Betriebsanleitung
Value / Range
Remark [Unit]
Remark [Unit]
D

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis