SPECIFIED CONDITIONS OF USE
The slide compound mitre saw is intended for sawing solid and
bonded wood with or without glued veneer, plastics, and materials
similar to wood.
The slide compound mitre saw is intended to be used only by adult
operators who have read the instruction manual and understand
the risks and hazards.
The slide compound mitre saw is designed to be fixed at the base
to a solid bench top. If the base is not securely fixed, the whole
machine may move during cutting operations, which increases the
possibility of serious personal injury.
The slide compound mitre saw is designed make bevel and mitre
cuts. The capacities for the various cuts are provided in the product
specifications in this manual.
The slide compound mitre saw is to be used in dry conditions, with
excellent ambient lighting and adequate ventilation.
The slide compound mitre saw is intended for consumer use and
should only be used as described above and is not intended for any
other purpose.

RESIDUAL RISK

Even when the slide compound mitre saw is used as prescribed,
it is still impossible to completely eliminate certain residual risk
factors. The following hazards may arise and the operator should
pay special attention to avoid the following:
• Risk of contact with uncovered parts of the rotating saw blade.
• Kick-back of work pieces or parts of work pieces due to improper
adjustment or handling.
• Catapulting of faulty carbide tips from the saw blade.
• Damage to the respiratory system.
NOTE: Wear respiratory protection masks containing filters approp-
riate to the materials being worked.
Ensure adequate workplace ventilation. Do not eat, drink or smoke
in the work area.
Damage to hearing if effective hearing protection is not worn.
WARNING
Dust from certain paintsm coatings and materials maycause
irritation or allergic reactions to the respiratory system. Dust from
wood such as oak, beech, MDF and others are carcinogenic.Material
containing asbestos should only ever be worked or processed by
qualified specialist operators.
WARNING
Injuries may be caused, or aggravated, by prolonged use of a tool.
When using any tool for prolonged periods, ensure you take regular
breaks.
KNOW YOUR PRODUCT
See page A.
1. Handle, insulated gripping
surface
2. Switch trigger
3. Safety lock lever
4. Outer flange
5. Saw blade
6. Lower guard
7. Fixed fence
8. Kerf plate
9. Turn table lock handle
10. Top handle
11. Upper guard
12. Dust chute
13. Linear rod stop knob
14. Clamp
15. Bevel angle lock lever
16. Sliding fence
17. Workpiece holder
18. Extension bar
19. Mounting holes x4
20. Turntable
21. Mitre scale
22. 45° bevel angle adjustment
screw
23. 90° bevel angle adjustment
screw
24. LED switch
REPLACEMENT LIST
• PS216L3: Mitresaw EN 847-1/ ø216 x ø30 x 2,4 / 40T / HW / n max.
7000 min-1 (Page A: No. 5)
• Kerf plate (Page A: No. 8)

MAINS CONNECTION

Connect only to single-phase AC system voltage as indicated on
the rating plate. It is also possible to connect to sockets without an
earthing contact as the design conforms to safety class II.
Appliances used at many different locations including wet room
and open air must be connected via a residual current device (FI,
RCD, PRCD) of 30mA or less.
Only plug-in when machine is switched off.
Keep mains lead clear from working range of the machine. Always
lead the cable away behind you.
Before use check machine, cable, and plug for any damages or
material fatigue. Repairs should only be carried out by authorised
Service Agents.
A power spike causes voltage fluctuations and may affect other
electrical products in the same power line. Connect the product
to a power supply with an impedance equal to 0.3 Ω  to minimize
voltage fluctuations.
Contact your electric power supplier for further clarification.
MAINTENANCE
Do not modify this saw in any way or use accessories not approved
by the manufacturer. Your safety and that of others may be
compromised.
Do not use the saw if any switches, guards or other function of this
saw does not work as it is intended to. Return to an authorised
service centre for professional repair or adjustment.
Do not make any adjustments whilst the saw blade is in motion.
Always make sure the power plug has been removed from the
mains power source before making adjustments, lubricating or
when doing any maintenance on the product.
Before and after each use, check your saw for damage or broken
parts and keep it in top working condition by replacing parts
immediately with spares approved by the manufacturer.
The blade is very hot after use, wear gloves or allow to cool before
maintenance or cleaning procedures.
Clean out accumulated dust using a brush or vacuum cleaner. Do
not use compressed air.
To assure safety and reliability, all repairs, including changing
brushes, should be performed by an authorised service centre.
Clean tool and guarding system with dry cloth.
The ventilation slots of the machine must be kept clear at all times.
If the replacement of the supply cord is necessary, this has to be
done by the manufacturer or his agent in order to avoid a safety
hazard.
25. Laser switch
26. Spindle lock button
27. Cutting depth adjustment
plate
28. Cutting depth adjustment
knob