5. Commissioning, operation
The welding sockets shall comply with EHEDG documents doc. 9
and doc. 35. With TIG welding, the surface quality must be R
µm. The weld seams must be free from defects on the wetted and
EN
non-wetted contact sides and must be butt welded.
For tank-mounted temperature measuring instruments the tank
cleaning devices shall be positioned in such a way that the instrument
can be assessed and is perfectly cleaned. Avoid spray shadows
during CIP cleaning.
Special instructions for in-line versions
In-line access units (e.g. VARINLINE
in horizontal pipes should be installed with a slight pipe inclination for
self-draining.
With in-line access units (e.g. VARINLINE
from the manufacturer and observe their installation instructions.
Specify the insertion length so that the active part of the sensor is
placed in the middle of the flow.
Specify the insertion length so that no collision or contact can occur
with sensors installed opposite.
5.2 Zero point setting
Zero point setting can be made with a slotted screwdriver or open-ended
spanner at the back of the case, as shown.
14
) and instrumentation T-pieces
®
), use the original seals
®
WIKA operating instructions model TG58SA
≤ 0.8