3. Installation
The electrical and mechanical installation and gas
connection must be carried out by specialised personnel.
The electrical appliance is designed to be built-in to a 2-6 cm
thick worktop in the case of TOP installations; 2.5-6 cm in the
case of FLUSH installations.
The minimum distance between the hob and the wall must be
at least 5 cm from the rear part, at least 40 cm from the side
walls and at least 50 cm from the wall units above.
This product is a class 3 recessed appliance.
Fig. 1a /1b

3.1 Electrical connection

Fig. 3
-The installation must be performed by
professionally qualified personnel familiar
with the applicable installation and safety
standards ● The manufacturer declines
all responsibility to persons, animals or
property if the guidelines provided in this
handbook are not followed. ● The power
cable must be long enough to allow
removal of the hob from the worktop ●
Make sure that the voltage on the rating
plate on the bottom of the device
corresponds to that of the house where it
will be installed. ● Do not use extension
cords. ● Earthing is required by law ●
The earth power cable must be 2cm
longer than the other cables ● At no
point along the length of the cable must it
reach a temperature of 50° C above the
room temperature. ● The device is
intended to be permanently connected to
the electrical network, therefore, make
the connection to the fixed network via a
standard omnipolar switch, which
assures the complete disconnection of
the mains under category III over-voltage
conditions, and which is readily
accessible after the installation.
● Please note! Before reconnecting the
circuit to the mains power supply, make
sure that it is working correctly, always
check that the power cable is correctly
installed.
interconnection cable must be replaced
by the authorised technical support
service or by a person with similar
qualifications.

3.2 Gas connection

● The installation must be performed by
professionally qualified personnel familiar
with the applicable installation and safety
regulations. ● Connect the device to the
cylinder or gas supply in accordance with
the provisions of the standards in force,
making sure in advance that the
equipment is pre-configured for the type
of gas available.
● If not, refer to: "Adaptation to
different types of gas". ● Check also
that the supply pressure falls within the
values in the table: "Characteristics of
gas burners". ● Rigid/semi-rigid metal
connection ● Make the connection with
metal fittings and pipes (also flexible) to
avoid straining the internal parts of the
appliance. ● When installing flexible
pipes, make sure that, when fully
extended, their length does not exceed 2
metres. ● Only use pipes that comply
with the national standards in force. ●
N.B. - Once the installation is complete,
check that the entire connection system
is properly sealed with a soapy solution.