M.-Nr. 09087201
No.
Mat. no.
Designation
1
09877430
Coding plug MFM 3-5, AWG
1
09877420
Coding plug WRG 1, AWG
1
06886880
Coding plug MFM 53X, AWG 20
1
09616190
Coding plug N1Q-ST11a, AWG
4
01283130
Circuit board spacer
1
07993080
Blue 6-pin screw terminal strip
1
09192910
Green 7-pin screw terminal strip
1
09001600
Orange 4-pin terminal strip
1
09001580
Green/yellow 4-pin terminal strip
1
09001560
Blue 4-pin terminal strip
1
07991340
Grey 4-pin terminal strip
1
07717500
Connection wire, brown AWG 20 x 90
1
05280290
Cable tie bracket 150-001930
1
09083140
Liquid dispensing accessory
The liquid dispensing module accessory (7-12) (mat. no.: 09083140) contains the following components:
Included parts
No.
Mat. no.
Designation
1
09082720
Wiring diagram PW 6107–6207 module 3
6
05662760
M12 x 1.5 cable gland
6
05662200
M12 x 1.5 hex nut
6
05662770
M20 x 1.5 cable gland
6
05662280
M20 x 1.5 hex nut
Preparatory work
A
Disconnect the machine from the power supply and ensure that it cannot be switched on again in error.
A
If available, disconnect the machine from the gas supply.
A
Remove one screw on the left and right of the machine lid.
A
Lift the front of the lid a hand's width and push it back, detaching the centring cones at the back of the lid from the
connection strip.
A
Remove the lid upwards.
Installing the liquid dispensing module
A
Insert the EZL 235 electronic module (2) with 4 spacers (1) into the existing holes of the lateral machine frame;
see Fig. 1.
A
Insert the terminal strips (3) in the existing holes on the machine frame; see Fig. 1.
Positioning of the terminal strips (see Fig. 2):
- Terminal strip 1X3-4 = orange
- Terminal strip 2X3-4 = grey
- Terminal strip 3X3-4 = blue
- Terminal strip 4X3-4 = green/yellow
A
Connect the existing orange 1X3-4, grey 2X3-4 and blue 3X3-4 terminal strips on the machine frame to the new
terminal strips.
A
To connect the terminal strips, bridge the orange 1X3-4, grey 2X3-4 and blue 3X3-4 terminal strips with the black
connection wire (5); see Fig. 2.