Herunterladen Inhalt Inhalt Diese Seite drucken

Ambient Conditions - HEIDENHAIN EIB 5000 Betriebsanleitung

Vorschau ausblenden Andere Handbücher für EIB 5000:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 6
Interfaces
When operated with HEIDENHAIN cables.
Consider the voltage drop.
1)
Optimized for the specified interface (also applies to the pin layout)
For more information, see Product Information document, ID 1309514

Ambient conditions

Operating temperature
Storage temperature
Air humidity
Elevation
Common
Protection
Directives and standards
Emission
Immunity
EMC Directive
Product standard for adjustable speed electrical power drive systems
Standard for electrical equipment for measurement
66
EIB 5181: 0 °C to 40 °C, no condensation
EIB 52xx: 0 °C to 70 °C, no condensation
EIB 5291S: 0 °C to 60 °C, no condensation
–30 °C to 70 °C, no condensation
Max. 75 % in continuous operation
EIB 52xx, EIB 5181: max. 2000 m above sea level
EIB 5291S: max. 1000 m above sea level
EIB 5181: IP 20
EIB 52xx: IP 65 (when engaged)
EN 50370-1
EN 50370-2
2014/30/EU
EN 61800-5-1
EN 61010-1