Specifications
Product
Dimensions
Temperature sensor models
1)
In cold condition, a temperature of 10 °C is output; in switched condition, the max. temperature of 200 °C is output.
2)
EIB 521x: as opposed to other variants, a temperature of 250 °C is output in switched condition.
3)
EIB 5291S: cold condition 10 °C, switched condition 250 °C (if configured on PTC, otherwise -300 °C)
Electrical data
DC supply voltage from
PELV
HEIDENHAIN | EIB 5000 | Operating Instructions | 04/2021
EIB 5181: approx. 165 mm x 31 mm x 107 .2 mm (with top hat rail: 118 mm)
EIB 52xx: approx. 64 mm x 98 mm x 38.5 mm
KTY 84-130
PT1000
PTC
1) 2) 3)
PTC triplet
1) 2) 3)
Three KTY 84-130 sensors with a common reference
EIB 5181: 4.5 V to 5.5 V
EIB 521x: 3.6 V to 14 V
EIB 528x: 4.5 V to 5.5 V
EIB 5291S: 16 V to 28.8 V; up to DC 36.0 V possible without impairment of functional
safety