Multiple errors will be alternated on the display.
The dosing is automatically continued by Flow and Level after the elimination
of any problems.
The resetting of the Limit error message is carried out using the OK button.
The switch-on delay follows. This may also be cancelled using OK.
 ! – Additional display in temperature range with temperatures < 5°C
 Min. alarm and Max. alarm for pH and Redox
see section 4.4 + 4.5 for pH and 5.4 + 5.5 for Redox
3

Menu mode/changing parameters

Stop
Manual
control
control
unit
System
Control
settings
unit pH
Factory
Calibration
Settings
Date
Set point
Time
P-band
Language
Min. alarm
Configuration
Max. alarm
Reset time
IDS 2
Hold-back time
Delay
8 min
Min. degree
Limit pH
120 min
Max. degree
Limit
100 %
Disinfection
120 min
Control
unit
disinfection
Testing of
probe
Set point
7,2
650 mV
P-band
-1
100 mV
Min. alarm
6,8
550 mV
Max. alarm
7,6
750 mV
Reset time
0
0
Hold-back-time
0
0
Min. degree
15 %
10 %
Max. degree
100 %
34
WLAN
Test mode
set-up
Web set-up
Pump pH
mode
Pump
Manual set-
disinfection
up
Alarm relay
IP address
Level of pH
WLAN SSID
Level of
WLAN
disinfection
password
MAC
Flow sensor
address
Flow rate
Input pH
Input Redox
Input temp.
Input Cl
CLE 3
Input Cl
CLB 3