Herunterladen Inhalt Inhalt Diese Seite drucken

Using The Control Unit; Display In Operating Mode; Changing Between Operating Mode And Set-Up Mode - swim-tec CL2 Deluxe Salz 2,4 l/h Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
Swim-tec CL2 Deluxe pH/Rx

2. Using the control unit

2.1 Display in operating mode

Comes up briefly when device is switched on
and when changing from operating to set-up
mode.
Swim-tec
The display of the current pH measurement is
visible in the first line of the display. The per-
centage figure after the pH figure shows at what
% performance the peristaltic dosing pump is
working to dose pH-Minus or pH-Plus.
If the display reads „—" instead of showing the
value, this means the pH or the Rx-electrode or
both are not connected to the controller.
pH: 7,20
0 %
Temp. 19°C
0 %
The second line of the display shows the tem-
perature and the redox potential alternately.
2.2
Changing between operating mode
and set-up mode:
Operating mode:
pH: 7,20
Temp. 19°C
The control unit is functional when in operating
mode. The currently measured values are dis-
played and as required, the dosing pumps are
activated.
pH: 7,80
Rx: 650 mV
pH: —-
0 %
Rx: 250 mV
0 %
0 %
0 %
↑ 60 %
0 %
The arrow before the % of dosing performance
means that an alarm value has been exceeded (↑)
or undershot (↓).
pH: 7,80
Rx: 650 mV
If „Limit" appears in a line, the security switch-
off for the parameter concerned has been acti-
vated. For deactivation, see sections 5.4 and 5.5
below.
Set-up mode:
Stop
controller
pH
controller
Disinfection
controller
System
settings
Press the Mode button once to enter set-up
mode. If you press Mode again, you return to
operating mode. Use the arrow keys to select
the desired option.
Stop controller: Function for interlocking the
pH controller: Settings for pH-value control
Disinfection controller: Settings for disinfect-
System settings: Entry of date and time, set-
27
↑ 60 %
Limit
Mode
dosing pumps
ant dosing.
tings for time delay at the
start-up and for dosing time
limit.

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis