Herunterladen Inhalt Inhalt Diese Seite drucken

WIKA DG-10 Betriebsanleitung Seite 13

Digitalmanometer
Vorschau ausblenden Andere Handbücher für DG-10:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

5. Commissioning, operation
Sealing of the process connection
Parallel threads
per EN 837
For sealing the process connections with parallel
threads, use flat gaskets, lens-type sealing rings
or WIKA profile sealings at the sealing face
For information on sealings, see WIKA data sheet AC 09.08 or at www.wika.com.
Rotatability of the case
The case of the model DG-10-E can be rotated through 300°, thus the
display can be read from almost any position.
CAUTION!
Damage to the instrument
The instrument may be damaged by improper turning of the
case.
Do not turn the case forcibly past the stop point.
WIKA operating instructions digital pressure gauge, model DG-10
per DIN 3852-E
.
Tapered threads
NPT, R and PT
For sealing process connections with tapered
threads, the sealing is made in the threads
using additional sealing material, e.g. PTFE tape
(EN 837-2).
EN
300°
13

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis