Herunterladen Inhalt Inhalt Diese Seite drucken

Wheel Data Entry For Wheel Balancers With An Ultrasonic Sensor (If Installed) - TECO 680 Original Anleitungen

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

ALU 2P
ALU 1P
Returning the arm to the rest position makes it possible for the operator to change this set-
ting by selecting and using the Enter button to press the icon.
If this is the case, the
balancing programme switches from ALU 1P to ALU 2P and vice versa.
DETECTion PlanS BY PoinTEr
laSErBlaDE (if present)
The detection of the geometrical data relative to the real
balancing planes for the application of adhesive weights,
can be facilitated by the laser line on the lever of the
automatic detector.
To enable this line it is necessary to press the button on
the automatic arm (A, Fig. 16a).
The laser line is thus visible inside the rim for 10
seconds, after which, if necessary, the button on the
16a
automatic arm must be pressed again.
Wheel data entry for wheel balancers with an ultrasonic sensor
(if installed)
To enter the distance, diameter and width values automatically, proceed as follows:
- bring the internal automatic measuring arm into contact with the inner side of the rim (Fig.15).
Take great care to position the arm correctly so as to ensure accurate data reading.
Operator's manual TECo 680 - 680 PlUS - 680 PlUS Pl
88

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

680 plus680 plus pl

Inhaltsverzeichnis