Technical Data

General Data
Operating mode:
Temperature range
Operation:
Storage:
Altitude:
Clearance and creepage
distances
Rated impulse voltage /
pollution degree:
EMC
Electrostatic discharge:
HF-irradiation
80 MHz ... 2.7 GHz:
Fast transients
on wires for supply A1-A2:
on signal and control wires:
Surge voltages
between
wires for supply:
between wire and ground:
HF-wire guided:
Interference suppression:
Degree of protection
Housing:
Terminals:
Housing:
Vibration resistance:
Shock resistance:
Acceleration:
Impulse length:
Number of shocks:
Climate resistance:
Terminal designation:
Wire fixing:
Fixing torque:
Mounting:
Weight:
Dimensions
Width x height x depth:
Continuous operation
± 0 ... + 50 °C
- 25 ... + 85 °C
≤ 2000 m
4 kV / 2 (basis insulation) IEC/EN 60664-1
8 kV (contact)
IEC/EN 61000-4-2
(Test degree 3)
10 V / m
IEC/EN 61000-4-3
2 kV
IEC/EN 61000-4-4
2 kV
IEC/EN 61000-4-4
1 kV
IEC/EN 61000-4-5
2 kV
IEC/EN 61000-4-5
10 V
IEC/EN 61000-4-6
Limit value class A*
EN 55011
)
*) The device is designed for the usage
under industrial conditions (Class A,
EN 55011). When connected to a low
voltage public system (Class B, EN
55011) radio interference can be gene-
rated.
To avoid this, appropriate measures
have to be taken.
IP 40
IEC/EN 60529
IP 20
IEC/EN 60529
Thermoplastic with V0-behaviour
to UL subject 94
according to IEC/EN 61496-1 (1997)
Amplitude 0.35 mm IEC/EN 60068-2-6
Frequency 10 ... 55 Hz
10 g
16 ms
1000 per axis on all three axes
0 / 050 / 04
IEC/EN 60068-1
EN 50005
Box terminals with self lifting wire
Protection and plus-minus scews M3.5
0.8 Nm
DIN rail
IEC/EN 60715
320 g
45 x 84 x 121 mm

UL-Data

The safety functions were not evaluated by UL. Listing is accom-
plished according to requirements of Standard UL 508, "general use
applications"
Nominal voltage U
:
N
Ambient temperature:
Switching capacity:
Ambient temperature 50°C:
Semiconductor outputs:
Wire connection:
Technical data that is not stated in the UL-Data, can be found
in the technical data section.
nfo

Standard Type

BH 5904.02/00MF2/61 DC24V
Article number:
• Output:
• All functions settable via rotational switches
• Nominal voltage U
:
N
• Width:

Characteristic

250
200
150
100
50
0
1
2
3
4
5
6
7
Switching current I
[A]
Safe breaking, no continuous arcing
under the curve, max. 1 switching cycle/s
Arc limit curve
27
DC 24 V
0 ... +50°C
Pilot duty B300
5A 250Vac G.P.
5A 24Vdc
24Vdc, 100 mA
60°C / 75°C copper conductors only
AWG 20 - 12 Sol Torque 0.8 Nm
AWG 20 - 14 Str Torque 0.8 Nm
0055225
2 NO contacts
DC 24 V
45 mm
8
BH 5904.02/00MF2 / 26.01.21 en / 306A