Setting - Dold SAFEMASTER BH 5904.02/00MF2 Betriebsanleitung

Ventilüberwachungsmodul
Vorschau ausblenden Andere Handbücher für SAFEMASTER BH 5904.02/00MF2:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Setting

SW. 10:
Selection of operating mode
Valve status sensor
0
S21-S22 : NC, S23-S24: NC
1
S21-S22 : NO, S23-S24: NC
2
S21-S22 : NO, S23-S24: NO
3
S21-S22 : NC, S23-S24: NC
4
S21-S22 : NO, S23-S24: NC
5
S21-S22 : NO, S23-S24: NO
6
S21-S22 : NC, S23-S24: NC
7
S21-S22 : NO, S23-S24: NC
8
S21-S22 : NO, S23-S24: NO
9
not allowed
Plate
The setting of the function of the BH 5904 is done with 4 rotational switches
located behind the front plate shown in the picture. The switches on the left
select the function on processor 1 and the switches on the right of processor
2. For both processors the setting must be the same.
Example for setup:
Function to be selected: status sensor on valve is C/O contact,
1 valve test per machine cycle, max. 1 s.
Set both upper switches to 5
Set both lower switches to 1
Time in which the valve has to react
SW 1
0
(s)
0.5
Valve monitoring mode
1 test per machine cyclic
Continuous monitoring of the valve
20
ch1
ch2
6
9
6
9
1
3
0
3
0
6
9
6
9
10
3
0
3
0
Inside view
1
2
3
4
0.61
0.72
0.83
0.94
Contact reinforcement
Without contact reinforcement
With contact reinforcement
5
6
7
8
1.05
1.16
1.27
1.38
BH 5904.02/00MF2 / 26.01.21 en / 306A