PARAMETER
VALUE
CoS2
no
Ch
APCh
Co.tE
no
Foto
rESi
FC.En
no
L.SW
Cor.0
EnCo
no
Si
i.Adi
no
Si
ASM
no
0.5" - 3.0"
FinE
no
Si
DESCRIPTION
Safety ribbon 2 input
This menu allows enabling the input for type 2 safety ribbon, that is to say
mobile ribbons
Input disabled
Input enabled during the closing and disabled during the opening
Input enabled in opening and closure
Test of the safety edges
This menu allows setting the method of control of the safety edges
working.
Test disabled
Test enabled for optical safety edges
Test enabled for conductive rubber safety edges
End of Stroke Inputs
End of stroke inputs are disabled
End of stroke equipped with a normally close switch
End of stroke in series of motor winding
Encoder Input
Input disabled
Input enabled
Enabling the ADI device
This menu makes it possible to enable operation of the device connected
to the ADI connector.
Si
PLEASE NOTE: selecting
and pressing MENU accesses the
configuration menu for the device connected to the ADI connector.
This menu is managed by the device itself and is different for each device.
Please refer to the manual for the device.
Si
If the
option is selected, but no device is connected, the display will
show a series of dotted lines.
Exiting the ADI device configuration menu returns to the
Interface disabled
Interface enabled
Anti-skid
When an opening or closing operation is interrupted by a command or
for the intervention of the photocell, the set-up time for the opposite
movement would be excessive, so the control unit operates the motors
only for the time necessary to recover the actually covered journey.
This could be not sufficient, particularly in the case of very heavy gates,
as because of the inertia at the inversion moment the gate runs an extra
space in the previous direction that the control unit is not able to take
into account. If after an inversion the gate does not return exactly to the
starting position, it is possible to set an anti-skid time that is added to the
time calculated by the control unit in order to recover the inertia.
Function disabled
Anti-skid time
End of Programming
This menu allows to finish the programming (both default and
personalized) saving the modified data into memory
It does not exit from the program menu
It exits from the program menu by storing the setup parameters
i.Adi
- 42 -
DEFAULT
MEMO
no
no
no
no
no
option
no
no