WIRELESS EXHAUST AIR CONTROL AS-6020.
Assembly and operating instructions for an exhaust
air controller Model AS-6020.3 (radio version)
Thank you for purchasing the PROTECTOR AS-6020.3
Exhaust Air Controller.
NOTE
Installation of the receiver must be performed by a
qualified electrician!
GENERAL
This device can be used as an exhaust air control
device, as an aid to monitor fresh air supply when
commissioning an exhaust air device (fume extractor
hood, fan etc...). This cannot replace self-monitoring
to ensure fresh air supply, but it can be supportive.
This device only activates the exhaust air system in the
event of pressure equalisation when a window or door
is opened. The additional fresh air streaming in can
thus be drawn in from the outside. You can also use
this device to selectively switch devices or lamps ON or
OFF, for instance when a door or a window is closed or
opened. This, for example, enables significant reduction
of energy costs for heating or air-conditioning devices.
ATTENTION
When using this device for exhaust air control,
the shutter must be open to ensure adequate
inflow offresh air!
USE OF ADDITIONAL TRANSMITTERS
(MAX. 8 DEVICES)
The device functionality can be extended by adding
more transmitters (window contacts) with the result
12
3
that the extractor hood is not limited to a single
window only. Each individual transmitter can activate
the exhaust air device.
FUNCTION SELECTOR SWITCH
The code button (1) on the receiver allows you to
select one of two functions (operating directions),
which are displayed by the LED (4) showing red or
green. If the LED shows green (OPEN) the connected
device is switched on when a window is open (e.g.
in air extraction control mode). If the LED shows red
(CLOSED) the connected device is switched off when a
window is open (e.g. air-conditioning, heating device).
NOTE
In order to reverse the operating direction, the code-
switch (1) must be operated once and then the
window opened and closed again. The set operating
direction is retained even after power failure.

RECEIVER INSTALLATION

ATTENTION
Installation must be performed by a qualified
electrician! The device is for indoor use only!
Connection example 1
The receiver can be installed over or under plaster in a
distribution or switch box or socket with a 60 mm min.
diameter. If required, the fastening ears can be broken off.
Connection example 2
In the case of exhaust air devices with speed steps,
the receiver is connected to the fan motor supply only,