Isolationskoordination nach IEC 60664-1/IEC 60664-3
Bemessungsspannung ....................................................................... 250 V
Überspannungskategorie (OVC) ............................................................... III
Versorgungspannung
RCMB42...-25
Nennspannung U
............................................................. DC 24 V
S
Nennspannungsbereich U
Nennstrom .................................................110 mA (RCMB420-25)
......................................................................70 mA (RCMB422-25)
Interner Verpolungs- und Kurzschlussschutz ................................ja
RCMB42...-2
Nennspannungsbereich U
............................................................................... DC 150...220 V
Nennstrom ........................................................................ < 30 mA
Toleranz des Frequenzbereichs von U
Schaltglieder
Alarmrelais K1, K2 .................................................................I
...................................................................................... I
Schaltglieder ....................................................................... 2 x 1 Schließer
Arbeitsweise ............................................................................. Ruhestrom
Elektrische Lebensdauer ...............................................10.000 Schaltspiele
Kontaktdaten nach IEC 60947-5-1
Gebrauchskategorie .............................................................. AC-14/DC-13
Bemessungsbetriebsspannung U
Bemessungsbetriebsstrom I
................................................................. 5 A
e
Minimale Kontaktbelastung
(Referenzangabe des Relais-Herstellers)................................10 mA/5 V DC
Normen
IEC 60364-7-722
IEC 62752
DIN VDE 0100-722:2016-10; VDE 0100-722:2016-10
Alle Rechte vorbehalten.
Nachdruck und Vervielfältigung
nur mit Genehmigung des Herausgebers.
Bender GmbH & Co. KG
Postfach 1161 • 35301 Grünberg • Deutschland
Londorfer Str. 65 • 35305 Grünberg • Deutschland
Tel.: +49 6401 807-0 • Fax: +49 6401 807-259
E-Mail: info@bender.de • www.bender.de
........................................ DC 18...36 V
S
................... AC 110...240 V, 50/60 Hz
S
...................... –5...+15 %
S
Δn
≥ 30 mA (RMS)
Δn
...................................................... 250 V
e
Technical data
Insulation coordination acc. to IEC 60664-1/IEC 60664-3
Rated voltage .................................................................................... 250 V
Overvoltage category (OVC) .................................................................... III
Supply voltage
RCMB42...-25
Nominal voltage U
Nominal voltage range U
Nominal current .................................................110 mA (RCMB420-25)
............................................................................ 70 mA (RCMB422-25)
Internal protection against reverse polarity and short circuit ............ yes
RCMB42...-2
Nominal voltage range U
..................................................................................... .DC 150...220 V
Nominal current ....................................................................... < 30 mA
Tolerance of the frequency range of U
Switching elements
≥ DC 6 mA;
Alarm relays K1, K2 ...............................................................I
...................................................................................... I
Switching elements ........................................................2 x 1 N/O contacts
Operating principle ............................................................... N/C operation
Electrical endurance, number of cycles ............................................10,000
Contact data acc. to IEC 60947-5-1
Utilisation category .................................................................AC-14/DC-13
Rated operational voltage U
Rated operational current I
Minimum contact load
(relay manufacturer's reference) ...........................................10 mA/5 V DC
Standards
IEC 60364-7-722
IEC 62752
DIN VDE 0100-722:2016-10; VDE 0100-722:2016-10
.................................................................... DC 24 V
S
............................................... DC 18...36 V
S
. .......................... .AC 110...240 V, 50/60 Hz
S
..............................-5...+15 %
S
............................................................ 250 V
e
.................................................................. 5 A
e
Reprinting and duplicating
only with permission of the publisher.
Bender GmbH & Co. KG
PO Box 1161 • 35301 Grünberg • Germany
Londorfer Str. 65 • 35305 Grünberg • Germany
Tel.: +49 6401 807-0 • Fax: +49 6401 807-259
E-Mail: info@bender.de • www.bender.de
≥ DC 6 mA;
Δn
≥ 30 mA (RMS)
Δn
All rights reserved.