Connecting external room thermostat
NOTICE
Use original accessories
To ensure reliable device operation, only connect
original accessories to the device.
4
3
2
Fig. 39: Connecting thermostat
1 Thermostat
3 Protective cap
✓ The device is in standby mode – the device is
switched off and the power plug is connected.
a) Remove the protective cap from the device
socket.
b) Plug the thermostat plug into the socket and
lock the plug.
c) Place the thermostat in a suitable position.
16
Device operation and
control
Safety instructions for operation
CAUTION
Risk of injury from burns on hot surfaces
The housing of the device and in particular the hot
air outlet side become very hot during operation.
Particular caution is required at places where chil-
dren or persons with a physical, sensory or mental
disability are present.
a) Never touch the housing or the hot air outlet
side of the device while it is in operation.
b) Wear protective gloves.
c) If children or persons with a physical, sensory
or mental disability are present near the device,
supervise them closely.
Prior to switching on
a) Make sure that the device is not standing on a
wet surface and that it is in an upright and sta-
ble position.
b) Make sure that there is fuel in the tank.
EN
1
2 Thermostat plug
4 Socket on device
c) Make sure that the power cord is not damaged.
d) Make sure that the device is connected to a
power socket with the correct voltage and pro-
tection (seeTechnical data and factory settings
[
42]).
e) Strictly adhere to all instructions in the Operat-
ing conditions are adhered to.
Switching device on
Fig. 40: Switching device on
1 Power cord
a) Set the device switch at the control panel to po-
sition [I].
 The device starts within a few seconds.
Should the device fail to start, refer to sec-
tion Malfunctions during operation
 The device is switched on and runs in continu-
ous mode.
Resetting device
If a malfunction occurs, the device is automatically
switched to fault mode and the reset button at the
control panel is lit. In this case, the device must be
reset.
✓ The reset button at the control panel is lit.
a) Eliminate the cause of the malfunction.
b) Press and hold the reset button for 2 seconds
until it is no longer lit.
 The device is now reset and can be switched on
again.
If you are unable to eliminate the cause of the prob-
lem, contact the HEYLO service department.
Oil heater KS 35 T
1
2
2 Device switch
[
37].