Herunterladen Inhalt Inhalt Diese Seite drucken

Intended Use; Improper Use; Foreseeable Misuses; Safety Devices - HEYLO KS 35 T Betriebsanleitung

Ölheizgerät
Vorschau ausblenden Andere Handbücher für KS 35 T:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

opposite side through the hot air outlet.
The exhaust gases are discharged through the ex-
haust gas pipe.
After the device is switched off, the fan continues to
run until the heat exchanger has cooled down.
NOTICE
Exhaust gas duct
It is the responsibility of the device operator to in-
stall an adequate exhaust gas duct. The exhaust
gas duct used must be at least one metre long and
protected with a rain hood. We recommend the use
of HEYLO original accessories and spare parts.
Operation with room thermostat
The device can be run in conjunction with a room
thermostat so that it is operated on the basis of the
actual room temperature.
14.2.1

Intended use

The device is a heater for closed rooms and outdoor
spaces (e.g. warehouses, workshops, construction
sites).
Intended use also includes compliance with the op-
erating conditions (see Operating conditions
Any use other than the specified is deemed improp-
er. Improper use shall void all warranty cover.
See also
 Technical data and factory settings
14.2.2

Improper use

Any use other than the intended is prohibited. Im-
proper use can lead to danger.
– Improper use includes interference with safety-
relevant components of the device.
– Improper use includes further operation of the
device under inadmissible operating conditions
and insufficient maintenance .
14.2.3

Foreseeable misuses

Reasonably foreseeable misuse includes:
– Operation under inadmissible operating condi-
tions, non-adherence to safety clearances
– Operation in rooms with insufficient ventilation or
operation without suitable exhaust gas duct
– Outdoor operation without frost and rain protec-
tion of exhaust gas duct
– Unsupervised operation without installed room
thermostat
EN
14.3
If safety devices are not installed properly or config-
ured incorrectly, there is a risk of injury. Do not
modify, dismantle or disable safety devices. All safe-
ty devices must be freely accessible at all times.
Familiarize yourself with the safety devices, in order
to be able to prevent or minimise the risk of injury
and/or damage to property.
3
Fig. 29: Safety devices
1 Housing
[
28]).
3 Hot air outlet
[
42]
Fig. 30: Safety devices of combustion chamber
1 Safety temperature
limiter (STL)
The device is equipped with the following safety
devices:
– Safety temperature limiter triggering a safety
shut-down of the device in case of overheating.
– Photocell monitoring the flame in the combustion
chamber to prevent operation of the device with-
out a flame.
Oil heater KS 35 T

Safety devices

2 Safety guard
2 Photocell (flame
monitoring)
1
2
31 / 44

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

2202603