Herunterladen Inhalt Inhalt Diese Seite drucken

Restarting After An Unscheduled Downtime; Power Failure; Malfunctions During Operation - HEYLO KS 35 T Betriebsanleitung

Ölheizgerät
Vorschau ausblenden Andere Handbücher für KS 35 T:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

NOTICE
Cleaning combustion chamber and check-
ing exhaust gas values
If there is soot in the combustion chamber, it might
be necessary to clean it.
After the combustion chamber has been cleaned,
the device settings must be adjusted for optimised
combustion. This must be done by a trained spe-
cialist.
17.1
Restarting after an unscheduled
downtime

Power failure

After a power failure, the safety temperature limiter
(STL) may be tripped and/or the burner may have
gone into failure mode.
a) Press the reset button at the control panel and
reset the STL and the burner.
b) Start the device.
 If the device returns to failure mode, there
might be a problem with overheating.
In this case, shut down the device and ar-
range for the repair to be carried out.
17.2

Malfunctions during operation

NOTICE
If the device is supplied with power through the
mains cord, work on the electrical system must only
be carried out by a qualified electrician or an electri-
cally instructed person in accordance with DGUV
regulation 3 or DIN VDE 0105-100 or DIN VDE
0701-702.
Have all repair work on the electrical, gas and oil
connections carried out by HEYLO service person-
nel or by HEYLO service partners.
To identify and eliminate problems, refer to the trou-
bleshooting table below:
Malfunction /
Possible cause / remedy
message
Device fails to
Device switch in position [0]
start or shuts
Set device switch to position [I].
down
No power supply
– Connect the power plug to the
socket.
– Check the voltage of the power
supply system.
Power cord defective
EN
Malfunction /
Possible cause / remedy
message
Contact the HEYLO service depart-
ment.
Electronics blocked or defective
– Reset device (see Device opera-
tion and control
– Contact the HEYLO service de-
partment.
Incorrect room thermostat set-
tings (optional equipment)
Set the room thermostat to a tem-
perature that is higher than the cur-
rent ambient temperature.
No fuel
Top up fuel and reset the device.
Fuel line blocked
– Empty the tank and fill it with
clean fuel (see Checking and
cleaning the device
– Clean the filter (see Checking and
cleaning the device
– Contact the HEYLO service de-
partment.
Insufficient oil pressure
Contact the HEYLO service depart-
ment.
Nozzle blocked
Contact the HEYLO service depart-
ment.
Incorrect ignition electrode set-
tings
Contact the HEYLO service depart-
ment.
Device emits
Fuel line blocked
smoke
– Nozzle dirty (for cleaning instruc-
tions, see Checking and cleaning
the device
– Dirt/paraffin in fuel (see Checking
and cleaning the device
– Incorrect pump pressure (see
Checking and cleaning the device
[
39]).
– Clean the filter (see Checking and
cleaning the device
– Contact the HEYLO service de-
partment.
Air inlet opening blocked
Unblock the air inlet opening.
Oil heater KS 35 T
[
35]).
[
39]).
[
39]).
[
39]).
[
39]).
[
39]).