Oil heater KS 35 T
NOTICE
Fire equipment testing in Germany
In Germany, fire equipment that is to be operated
for more than 3 months after commissioning must
be inspected by a fire safety expert in accordance
with the BImSchV.
Connection to flue pipe
When operating the device indoors, the exhaust gas
duct must be connected to a flue pipe.
Fig. 36: Flue connection
1 Flue connection pipe
A Diameter of flue
connection pipe (see
Technical data and
factory settings
[
42])
Exhaust gas duct with flue pipe
When using a flue pipe, observe the prescribed
safety distances. Install a flue duct (out of building or
to wall gap) as shown in the figures below.
34 / 44
1
2
2 Exhaust gas pipe
Fig. 37: Exhaust gas release to outdoor air
A > 1 m
C as short as possible
E Wind protection
Fig. 38: Exhaust gas release to wall gap
A > 1 m
C as short as possible
Connecting device to power supply
a) Connect the device to a power socket that is
earthed or protected by an integrated RC circuit
breaker (see Technical data and factory settings
[
42]).
 The device is now installed and ready for opera-
tion.
B ≥ 1 m
D > 5°
B ≥ 1 m
D > 5°