take care that the battery acid does not get into your skin, eyes or mucous membranes! Dispose of leaking and old
batteries according to the regulations.
Replace old batteries with batteries of the same type!
Do not use rechargeable batteries. They have a too low voltage!
Remove the batteries from the battery compartment when you are not using the remote control for more than
a month. Make sure that the battery compartment is always closed when the battery is inserted!
Only operate the device when the battery compartment is closed!
Non-rechargeable batteries are not to be re-charged!
New batteries should not be used together with used batteries!
Always use batteries with the same type!
Never short the terminals of the batteries!
Start up:
Attention:
In order to prevent your hearing from being stressed too much by the very loud alarm tone, do not hold
the device close to your head during the function check! To avoid frightening noise-sensitive persons such as small
children, do not hold the unit in the same room during the function check!
Attention:
Check the function of the smoke detector weekly!
Activation of the smoke alarm detector:
Insert the batteries into the battery compartment as described in the previous section. If the batteries are inserted
correctly (note the direction of the poles!), a short beep will sound and the LED will light up briefly. The smoke alarm
detector is now ready for operation.
Functional check:
Note: The test tone is much quieter than the actual alarm tone to protect your hearing! To check the function, keep
the TEST button pressed for approx. 3s. The alarm tone sounds and the LED lights up red. This is to check whether
the electronics, the alarm of the smoke alarm detector and the batteries are functioning. The alarm tone stops
immediately after releasing the TEST button.
Note: If neither the alarm sounds nor the LED flashes, the batteries may be flat or the unit may be defective. First
replace the batteries. If the unit still does not work, it is defective. In this case, the unit must be replaced with a new
functioning unit!
Temporary muting the Alarm:
In the event of a false alarm, the alarm tone can be muted for approx. 10 minutes. It is essential to ensure that the
alarm was not triggered by a fire! To mute the alarm temporarily, press the TEST button. Then open doors and
windows to clean the air. If the air still has a high number of combustion particles after 10 minutes, the alarm will
sound again. The mute function can be repeated as often as required by pressing the TEST button. Activation of the
mute function is not possible in case of excessive smoke development. To deactivate the mute function, press the
TEST button!
Recurrent self-test of the smoke alarm detector on its function:
The smoke alarm detector performs every 50 seconds a self-test. You can see this by a short blink of the LED.
Networking several devices with each other :
General information on networking:
Up to 15 units from the same manufacturer and the same product series can be networked together. The units should
not be installed and operated further than 35m apart. The following devices can be networked together: Smoke