3.2.6

Output Voltage Programming by External Voltage

Output Voltage of RFE1600 Series can be programmed by external voltage source between approximately
80%-120% for 24V, 32V, 48V and 80%-110% for 12V of nominal output voltage
(For Output voltage limits see Graph enclosed)
3.2.7

Current Programming by PMBus (Optional)

Over Current Protection (OCP) can be programmed by PMBUS with a range of 50% ~ 110% of Nominal Output Current.
If PMBus is used for current programming, the Reference voltage will not be fixed to 5V but variable.
RFE1600
V_PROG.
J1-3
-SENSE
J1-1
Figure 3–8:
Control by Ex. Voltage
Vout [V]
Voltage Programming
60
50
RFE1600-48
40
RFE1600-32
30
RFE1600-24
20
RFE1600-12
10
0
0
1
2
V PROG [V]
Figure 3–9:
Output Voltage Limits
ATTENTION:
RFE1600
CURRENT PROG.
Figure 3–10:
Current Programming by PMBus
.
+
0~5V
58
38.4
29
13.2
3
4
5
J1-4
V_REF
J1-5
14
Inhaltsverzeichnis