Herunterladen Inhalt Inhalt Diese Seite drucken

TDK-Lambda RFE1600 Serie Bedienungsanleitung Seite 22

Inhaltsverzeichnis
LIVE CIRCUITS
Operating personnel must not remove the RFE1600-xy unit cover.
No internal adjustment or component replacement is allowed by non-TDK Lambda qualified service personnel. Never
replace components with power cable connected. To avoid injuries, always disconnect power, discharge circuits and
remove external voltage sources before touching components.
Restricted Access Area: RFE1600-xy units should only be installed in a Restricted Access Area. Access should be available to
service personnel only.
PARTS SUBSTITUTIONS & MODIFICATIONS
Parts substitutions and modifications are allowed to authorized TDK Lambda service personnel only. For repairs or
modifications, the instrument must be returned to TDK Lambda service facility.
AC INPUT
Do not connect RFE1600-xv unit to mains supply exceeding the input voltage and frequency rating. The input voltage and
frequency rating is: 100-240V~, 50/60Hz. For safety reasons, the mains supply voltage fluctuations should not exceed
±10% of nominal voltage.
HEAT HAZARD
WARNING: Top, bottom and side surfaces may become hot when operating the unit continuously. To reduce the risk of
injury from a hot surface, allow the surface to cool before touching.
ENERGY HAZARD
The main output of RFE1600-xy units is capable of providing hazardous energy. Due to hazardous energy level the output
and connections therefore must not be user accessible. Manufacturer's final equipment must provide protection to service
personnel against inadvertent contact with output bus bars.
FUSE
Internal fuse is sized for fault protection and if a fuse was opened it would indicate that service is required.
Fuse replacement should be made by qualified technical personnel.
RFE1600-xy unit fuse rating is described below. F101: F20A H 250Vac.
OVERCURRENT PROTECTION:
A readily accessible branch circuit over-current protective device rated 30A max. Must be incorporated in the building
wiring. The protective device must be disconnect both supply line simultaneously.
9
Inhaltsverzeichnis
loading