Herunterladen Inhalt Inhalt Diese Seite drucken

Output Voltage Programming By External Voltage; Current Programming By Pmbus (Optional) - Tdk-Lambda Rfe2500 Serie Bedienungsanleitung

Inhaltsverzeichnis
3.2.6

Output Voltage Programming by External Voltage

Output Voltage of RFE2500 Series can be programmed by external voltage source between approximately
80%-120% for 24V, 48V and 80%-110% for 12V of nominal output voltage
(For Output voltage limits see Graph enclosed analog voltage programming 0.5V~5V)
3.2.7

Current Programming by PMBus (Optional)

Over Current Protection (OCP) can be programmed by PMBUS with a range of 50% ~ 110% of Nominal Output Current.
If PMBus is used for current programming, the Reference voltage will not be fixed to 5V but variable.
RFE2500
VOLTAGE PROG.
-SENSE
J1-1
Figure 3–8:
Control by Ex. Voltage
Vout [V]
Voltage Programming
60
50
RFE2500-48
40
30
RFE2500-24
20
RFE2500-12
10
0
0
1
2
VOLTAGE PROG
Figure 3–9:
Output Voltage Limits
ATTENTION:
RFE2500
CURRENT PROG.
Figure 3–10:
Current Programming by PMBus
J1-3
+
0~5V
58
29
13.2
3
4
5
. [V]
J1-4
V_REF
J1-5
14
.
Inhaltsverzeichnis
loading