LZS-A1500-3-001 POWER SUPPLY
Installation, Operation, and Maintenance Manual
IM-L L ZSA1500-3 3 -0 0 01
November 2013
Revision C

Werbung

Inhaltsverzeichnis
loading

Inhaltszusammenfassung für TDK-Lambda LZS-A1500-3-001

  • Seite 1 LZS-A1500-3-001 POWER SUPPLY Installation, Operation, and Maintenance Manual IM-L L ZSA1500-3 3 -0 0 01 November 2013 Revision C...
  • Seite 3: Inhaltsverzeichnis

    LZS-A A 1500-3 3 -0 0 01 Power Supply Table of Contents 1) Safety and Recommended Practices General safety instructions Safety Agency Approvals 2) RATINGS AND SPECIFICATIONS 3) FEATURES 4) GUIDE TO APPLICATION Safety Notice Input Voltage Output Voltage Overvoltage Protection Circuit Adjustment Overtemperature and Overvoltage Shutdown Auxiliary Control and Alarm Signals 5) FIGURES...
  • Seite 4: Safety And Recommended Practices

    LZS-A A 1500-3 3 -0 0 01 Power Supply 1 Safety and Recommended Practices 1 Sicherheitsvorschriften und Vorsichtsmassnahmen 1.1 General Safety Instructions 1.1 Allgemeine Sicherheitsanweisungen This power supply is a switch mode power Dieses Netzteil ist ein Primaerschaltregler Geraet supply for use in applications meeting a für Applikationen mit Verschmutzungsgrad 2.
  • Seite 5: Safety Agency Approvals

    LZS-A A 1500-3 3 -0 0 01 Power Supply 8. Openings in the product case are designed 8. Oeffnungen und Lochungen am Gehaeuse for ventilation and must not be obstructed sind fuer Lueftungszwecke vorgesehen und when the product is installed and/or operated. duerfen nicht abgedeckt werden.
  • Seite 6: Ratings And Specifications

    LZS-A A 1500-3 3 -0 0 01 Power Supply Emissions AC Line Conducted Emissions EN55022/EN55011 (0.15-30 MHz) Class B Radiated RF Emissions EN55022/EN55011 30-1000 MHz Class B Powerline Harmonics EN61000-3-2 Class A Limits Powerline Fluctuation/Flicker EN61000-3-3 Complies Immunity Electrostatic Discharge IEC61000-4-2 +/-8 kV Air +/-6 kV Contact...
  • Seite 7: Input Specifications

    LZS-A A 1500-3 3 -0 0 01 Power Supply Input Specifications Units LZS-A1500-3 Input Voltage Range*** Input Voltage Range*** VAC 85-265(47-440Hz) Single phase; 100-380 Input Current (RMS, maximum) 18 RMS Inrush Current (Peak, at cold start) 30A /110VAC; 40A /220VAC Power Factor Harmonics EN61000-3-2 Compliant Power Factor (at max output power)
  • Seite 8: Operating Modes

    LZS-A A 1500-3 3 -0 0 01 Power Supply Operating Modes Series Operation Yes (see Fig. 7) Parallel Operation Two or more identical units (see Fig. 6). (Use of D. con. terminal 5 will (with current sharing) provide current sharing to within 10% nominal of rated 60°C current.) Table 6 * Not backward compatible with the LZS-1500-3 power supply.
  • Seite 9: Protection Features

    LZS-A A 1500-3 3 -0 0 01 Power Supply Protection Features Output Voltage Range 18-29.4V Nominal Factory Set Point Overvoltage Protection (adjustable) 20-34V (Factory set to 31.0V) Overcurrent Protection Factory set to 110% min. and 130% max. Thermal Protection Self-resetting thermostat.* Fusing Internal Isolation Voltages...
  • Seite 10: Guide To Application

    LZS-A A 1500-3 3 -0 0 01 Power Supply 4. GUIDE TO APPLICATION 4.1 SAFETY NOTICE Dangerous voltages exist in this equipment. Observe the usual safety precautions when operating, wiring, or servicing to reduce the risk of shock or injury. 4.2 INPUT VOLTAGE See Table 3 on page 4.
  • Seite 11: Figures

    LZS-A A 1500-3 3 -0 0 01 Power Supply 5. Figures Figure 1 - PIN Assignments for TB201 and chassis mounted “D” connector Page. 9 3055 Del Sol Blvd • San Diego, CA 92154 • 1-800-LAMBDA-4 Revision C : November 2013...
  • Seite 12 LZS-A A 1500-3 3 -0 0 01 Power Supply LS = Local Sense S = Remote Sense Figure 2 - Typical Local Sense Connection LS = Local Sense S = Remote Sense Figure 3 - Typical Remote Sense Connection Page. 10 Revision C : November 2013...
  • Seite 13 LZS-A A 1500-3 3 -0 0 01 Power Supply LS = Local Sense S = Remote Sense Figure 4 - Remote Voltage Control with an External Programming Resistor or Voltage Source (Local Sensing) LS = Local Sense S = Remote Sense Figure 5 - Remote Voltage Control with an External Programming Resistor or Voltage Source (Remote Sensing) Page.
  • Seite 14 LZS-A A 1500-3 3 -0 0 01 Power Supply Figure 6 - Parallel Operation Page. 12 Revision C : November 2013...
  • Seite 15 LZS-A A 1500-3 3 -0 0 01 Power Supply Figure 7 - Series Operation Page. 13 3055 Del Sol Blvd • San Diego, CA 92154 • 1-800-LAMBDA-4 Revision C : November 2013...
  • Seite 16 LZS-A A 1500-3 3 -0 0 01 Power Supply Figure 8 - Outline Drawing Page. 14 Revision C : November 2013...
  • Seite 17 LZS-A A 1500-3 3 -0 0 01 Power Supply Figure 9 - Remote Output On/Off Control Figure 10 - Input Good, Inverter Good & Output Good Signals Page. 15 3055 Del Sol Blvd • San Diego, CA 92154 • 1-800-LAMBDA-4 Revision C : November 2013...